free hit counter

IBM 6C1 Service Manual page 177

Pseries 610
Table of Contents

Advertisement

Table 3. Firmware Error Codes. (continued)
Error Code Description
40D00200 Processor initialization failed.
40D00201 JTAG chip ID miscompare.
40D00202 Hot-swap SCSI backplane failure
40D00203 SCSI ID conflict on hot-swap disk drives
450000C0 Uncorrectable memory error. (checkstop)
450000C1 Memory ECC correctable error
(checkstop)
450000C2 Memory ECC correctable error threshold
exceeded (checkstop)
450000C3 Memory controller subsystem internal
error (checkstop)
450000C4 Memory address error (invalid address or
access attempt) (checkstop)
450000C5 Memory data error (bad data going to
memory) (checkstop)
450000C6 Memory bus/switch internal error
(checkstop)
450000C7 Memory time-out error (checkstop)
450000D0 System bus time-out error (checkstop)
450000D1 System bus parity error (checkstop)
Action / Possible Failing FRU
Location code will point to failing FRU.
Replace the failing FRU pointed to by
the location code.
Replace the hot-swap backplane.
Location: P2
1. Verify that there are no SCSI ID
jumpers on the hot-swap disk
drives. (The SCSI IDs are set
automatically by the hot-swap
backplane.)
2. Isolate the failing hot-swap drive
by removing all of the drives, then
reinstalling them one at a time
until the error occurs. The last one
that was reinstalled is the failing
drive.
3. Replace the hot-swap backplane.
Location: P2
Go to "MAP 1240: Memory Problem
Resolution" on page 49.
Go to "MAP 1240: Memory Problem
Resolution" on page 49.
Go to "MAP 1240: Memory Problem
Resolution" on page 49.
Go to "MAP 1240: Memory Problem
Resolution" on page 49.
Go to "MAP 1240: Memory Problem
Resolution" on page 49.
Go to "MAP 1240: Memory Problem
Resolution" on page 49.
Go to "MAP 1240: Memory Problem
Resolution" on page 49.
Go to "MAP 1240: Memory Problem
Resolution" on page 49.
1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
Chapter 5. Error Code to FRU Index
159

Advertisement

Table of Contents
loading

This manual is also suitable for:

6e1

Table of Contents