Table 3. Firmware Error Codes. (continued)
Error Code Description
460000C5 Mezzanine/system bus address parity
error. (checkstop)
460000C6 Mezzanine/system bus data parity error.
(checkstop)
460000C7 Mezzanine/system bus time-out, transfer
or protocol error. (checkstop)
460000D4 I/O expansion bus data parity or CRC
error (checkstop)
460000D5 I/O expansion bus data time-out, access
or other error. (checkstop)
460000D6 I/O expansion bus connection failure.
(checkstop)
460000D7 I/O expansion bus unit is not in an
operating state (power down, off-line).
(checkstop)
Action / Possible Failing FRU
1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
1. Replace the FRU as indicated by
the physical location code
displayed on the operator panel.
2. Check the service processor error
log for additional FRUs.
Chapter 5. Error Code to FRU Index