Step 1540-23
The adapter or device is probably defective.
If the supplemental medium is for an adapter, replace the FRUs in the following order:
1. Adapter
2. System board (see notes on page 35)
If the supplemental medium is for a device, replace the FRUs in the following order:
1. Device and any associated cables
2. The adapter to which the device is attached.
Repeat this step until the defective FRU is identified or all the FRUs have been
exchanged.
If the symptom did not change and all the FRUs have been exchanged, call service
support for assistance.
If the symptom has changed, check for loose cards, cables, and obvious problems. If
you do not find a problem, return to "Step 1540-1" on page 64 in this MAP and follow
the instructions for the new symptom.
Go to "MAP 0410: Repair Checkout" in the RS/6000 Eserver pSeries Diagnostic
Information for Multiple Bus Systems .
Step 1540-24
1. Ensure that the diagnostics and the operating system are shut down.
2. Turn off the power.
3. If you have not already done so, configure the service processor with the
instructions in note 6 on page 63 and then return here and continue.
4. Exit the service processor menus and remove the power cords.
5. Remove the service access cover (Model 6E1) or place the drawer (Model 6C1) into
the service position and remove the service access cover.
6. Record the slot numbers of the PCI adapters. Label and record the locations of any
cables attached to the adapters. Disconnect any cables attached to the adapters
and remove all the adapters.
7. Plug in the power cords and wait for OK on the operator panel display.
8. Turn on the power.
Does the system stop with the same error code displayed on the operator panel
that directed you to this MAP step?
NO
YES
Go to "Step 1540-26" on page 82.
Go to "Step 1540-25" on page 82.
Chapter 3. Maintenance Analysis Procedures (MAPs)
81