1-2. Major Component Specifi cations
(B) Outdoor Units
SPW-C606VH8
MODEL No.
Source
Controller P.C.B. Ass'y
Control circuit fuse
Compressor
Model....number
Source
Nominal output
Compressor oil
Coil resistance
(Ambient temperature 25°C)
Safety control
Overload relay models
Operation temperature
Crank case heater
Refrigerant amount at shipment
High pressure switch
Set pressure
Fan
Number...diameter
Air circulation
Fan speeds (Max.)
Fan motor
Model No.
Source
No. of pole
Nominal output
Heat exchanger
Coil
Rows...fin pitch
Face area
W
cc
Ω
Excessive current control, Discharge temperature control
Open °C
Close °C
kg
2
OFF
kg / cm
2
ON
kg / cm
mm
3
m
/ h
W
mm
2
m
1-261
SPW-C606VH8
380 - 400 - 415 V, 3 phase, 50 Hz
CR-C606VH8 (Microprocessor)
20A
C-9RVN273H0K
246V (DC) / 3phase / 60Hz (Inverter drive)
3,800
1,400
C – R : 0.552
C – S : 0.552
–
–
–
R410A - 2.75
–
–
–
1...ø490
3,900
~860 rpm (Inverter drive control)
SIC-71FW-D8120-4
~280V / 3 phase
8
120
Aluminium plate fin / Copper tube
2...1.4
0.748
1
R – S : 0.552