Appendix C: Selection Remote Predefined Functions
DX-SW4 Remote Switch Control (4-button/4-LED)
Switch Positions
ID
1 through 8
Function
0
00000000
Mute Input 1-4 (1)
1
10000000
Mute Input 1-4 (2)
2
01000000
Mute Input 5-8 (1)
3
11000000
Mute Input 5-8 (2)
4
00100000
Mute Group 1-4 (1)
5
10100000
Mute Group 1-4 (2)
6
01100000
Mute Group 5-8 (1)
7
11100000
Mute Group 5-8 (2)
8
00010000
Force On 1-4 (1)
9
10010000
Force On 1-4 (2)
10
01010000
Force On 5-8 (1)
11
11010000
Force On 5-8 (2)
12
00110000
Force Off 1-4 (1)
13
10110000
Force Off 1-4 (2)
14
01110000
Force Off 5-8 (1)
15
11110000
Force Off 5-8 (2)
16
00001000
Preset Recall 1-4 (1)
17
10001000
Preset Recall 1-4 (2)
18
01001000
Preset Recall 5-8 (1)
19
11001000
Preset Recall 5-8 (2)
20-255
For Future Updates
Appendix D: Level Remote Predefined Functions
DX-RVC Remote Volume Control (2-button/12-LED)
Switch Positions
ID
1 through 8
Function
0
00000000
Input Level 1A (1)
1
10000000
Input Level 1A (2)
2
01000000
Input Level 1B (1)
3
11000000
Input Level 1B (2)
4
00100000
Input Level 2A (1)
5
10100000
Input Level 2A (2)
6
01100000
Input Level 2B (1)
7
11100000
Input Level 2B (2)
8
00010000
Input Level 3A (1)
9
10010000
Input Level 3A (2)
10
01010000
Input Level 3B (1)
11
11010000
Input Level 3B (2)
12
00110000
Input Level 4A (1)
13
10110000
Input Level 4A (2)
14
01110000
Input Level 4B (1)
15
11110000
Input Level 4B (2)
16
00001000
Input Level 5A (1)
17
10001000
Input Level 5A (2)
18
01001000
Input Level 5B (1)
19
11001000
Input Level 5B (2)
20
00101000
Input Level 6A (1)
21
10101000
Input Level 6A (2)
22
01101000
Input Level 6B (1)
23
11101000
Input Level 6B (2)
24
00011000
Input Level 7A (1)
25
10011000
Input Level 7A (2)
26
01011000
Input Level 7B (1)
27
11011000
Input Level 7B (2)
28
00111000
Input Level 8A (1)
29
10111000
Input Level 8A (2)
30
01111000
Input Level 8B (1)
31
11111000
Input Level 8B (2)
Each of the predefined functions has two IDs (1) and (2) to allow two remote controls
to perform the same function.
Control 1
Control 2
Mute Input 1
Mute Input 2
Mute Input 1
Mute Input 2
Mute Input 5
Mute Input 6
Mute Input 5
Mute Input 6
Mute Group 1
Mute Group 2
Mute Group 1
Mute Group 2
Mute Group 5
Mute Group 6
Mute Group 5
Mute Group 6
Force On 1
Force On 2
Force On 1
Force On 2
Force On 5
Force On 6
Force On 5
Force On 6
Force Off 1
Force Off 2
Force Off 1
Force Off 2
Force Off 5
Force Off 6
Force Off 5
Force Off 6
Preset Recall 1
Preset Recall 2
Preset Recall 1
Preset Recall 2
Preset Recall 5
Preset Recall 6
Preset Recall 5
Preset Recall 6
Switch Positions
ID
1 through 8
Function
32
00000100
Output Level A (1)
33
10000100
Output Level A (2)
34
01000100
Output Level B (1)
35
11000100
Output Level B (2)
36
00100100
Output Level A&B (1)
37
10100100
Output Level A&B (2)
38
01100100
Group Level 1 (1)
39
11100100
Group Level 1 (2)
40
00010100
Group Level 2 (1)
41
10010100
Group Level 2 (2)
42
01010100
Group Level 3 (1)
43
11010100
Group Level 3 (2)
44
00110100
Group Level 4 (1)
45
10110100
Group Level 4 (2)
46
01110100
Group Level 5 (1)
47
11110100
Group Level 5 (2)
48
00001100
Group Level 6 (1)
49
10001100
Group Level 6 (2)
50
01001100
Group Level 7 (1)
51
11001100
Group Level 7 (2)
52
00101100
Group Level 8 (1)
53
10101100
Group Level 8 (2)
54-255
Reserved for future
updates
Control 3
Control 4
Mute Input 3
Mute Input 4
Mute Input 3
Mute Input 4
Mute Input 7
Mute Input 8
Mute Input 7
Mute Input 8
Mute Group 3
Mute Group 4
Mute Group 3
Mute Group 4
Mute Group 7
Mute Group 8
Mute Group 7
Mute Group 8
Force On 3
Force On 4
Force On 3
Force On 4
Force On 7
Force On 8
Force On 7
Force On 8
Force Off 3
Force Off 4
Force Off 3
Force Off 4
Force Off 7
Force Off 8
Force Off 7
Force Off 8
Preset Recall 3
Preset Recall 4
Preset Recall 3
Preset Recall 4
Preset Recall 7
Preset Recall 8
Preset Recall 7
Preset Recall 8
DX8 – 35