free hit counter

Sony SRW-5000 Maintenance Manual page 125

Hd digital
Hide thumbs Also See for SRW-5000:
Table of Contents

Advertisement

[F6] (CLEAN PLG) key
This menu checks the function of the cleaning roller solenoid.
c
While checking, the drum is rotating. So never touch the drum.
Checking
1. Press the [F6] (CLEAN PLG) key of the ALT SERVO CHECK menu to
display the CLEANING PLUNGER menu.
2. Press the [SET] key.
Check to see that the cleaning roller momentarily touches the drum and then
away from the drum at once.
c
The cleaning roller solenoid causes burning when it remains activating.
If the cleaning roller is not away from the drum, turn off the power immediately.
3. To finish the check, press the [F10] (EXIT) key.
. The drum rotation will stop.
4. Press the [F10] (EXIT) key while pressing the [SFT] (SHIFT) key.
5. Press the [F10] (EXIT) key after the message "Check Complete" is displayed to
return to the ALT SERVO CHECK menu.
In case of NG
. Check the mechanical abnormality.
. Check the cleaning roller solenoid driver circuit on the DR-508 board.
. Check the cleaning roller solenoid itself.
Cleaning roller
Cleaning roller solenoid
SRW-5000/5500
Locations of Cleaning Roller and Cleaning Roller Solenoid
F1
F2
F3
F4
DIAG
ALT
(Unthreading end state)
DRUM
ALT SERVO CHECK MENU
MOTOR
CLEANING PLUNGER
REEL
SHIFT
Press SET key.
PINCH
PLG
S REEL
BRAKE
T REEL
CLEAN
CAP
EXIT
BRAKE
PLG
REEL
F5
F6
F7
F8
F9 F10
[SET]
ALT SERVO CHECK MENU
PUSH SET(FOR ON)
CLEANER: OFF
[SET]
[SET]
ALT SERVO CHECK MENU
PUSH SET(FOR OFF)
CLEANER: ON
3-31