ALT + [F1] (META DATA) Key
m
. In SRW-5000, the meta data line setting menu appears.
Perform "M-DATA LINE Setting".
. In SRW-5500, the format selection menu appears.
Perform "Format selection".
Format selection (SRW-5500 only)
Press the [F2] (HDCAM-SR) key or [F3] (HDCAM) key
according to your system.
META DATA MENU SELECT
F1
HDCAM
F2
-SR
HDCAM
F3
F4
DIAG
ALT
F5
F6
F7
[F2] (HDCAM-SR) key
The meta data line setting menu appears. Perform "M-
DATA LINE Setting".
[F3] (HDCAM)
The meta data packet setting menu appears. Perform
"Setting the meta data 3 packet".
SRW-5000/5500
SELECT FORMAT
F2 : HDCAM-SR
F3 : HDCAM
EXIT
F8
F9
F10
In SRW-5000 or in selecting [F2]
on SRW-5500
n
The setting procedure of SRW-5500 is the same as that of
SRW-5000.
M-DATA LINE Setting
NVRAM
HDCAM-SR META DATA LINE SELECT
F1
CTL
F2
F3
F4
DIAG
F5
ALT
F6
F7
Select the three lines to write the meta data in the HDCAM-
SR recording.
Execution Procedure
1. Move the cursor to the item to be set using the [(]/[)]
keys.
2. Perform the line setting using the [F8] (PLUS)/[F9]
(MINUS) keys, MULTI CONTROL knob, or the [&]/
[*] keys.
3. Press the [F1] (NVRAM CTL) key.
OTHERS CHECK
F1
NVRAM CONTROL
F2
F3
F4
DIAG
ALT
F5
F6
F7
4. Select "SAVE ALL DATA" using the [(]/[)] keys,
and press the [F10] (EXIT) key.
. The changed data is written in the NV-RAM, and the
menu returns to the META DATA SETUP menu.
. When the changed data is not to be saved, select "NO
OPERATION", and press the [F10] (EXIT) key.
5. Press the [F10] (EXIT) key several times to return to
the OTHERS CHECK menu.
[F2]
[F2]
[F2] (HDCAM-SR)
[F2]
Meta Data 1 : Line 18
Meta Data 2 : Line 19
Meta Data 3 : Line 20
PLUS
MINUS
EXIT
F10
F8
F9
NO OPERATION
SAVE ALL DATA
EXIT
F8
F9
F10
3-61