6-5. CTL Head Height Check and Adjustment

Tools
. Alignment tape HR2-1B:
. Oscilloscope (Tektronix TDS3054B or equivalent)
. Tape guide adjustment driver (MW-261): J-6322-610-A
Preparation
1. Set the Alignment Tape
(1) Turn off the power.
(2) Set the alignment tape HR2-1B and put a
weight (about 1 kg) onto it.
(3) Turn on the power.
2. Connect the Oscilloscope
Connect the oscilloscope as follows:
CH-1: TP400/TC-104 board (CTL PB signal)
TRIG: TP200/SS-95 board (SV REF signal)
Oscilloscope setting:
CH-1: 0.5 V/DIV
TIME: 5 ms/DIV
6-22
8-960-076-41
. Connection of the oscilloscope
CH-1 : TP400/TC-104 board (CTL PB signal)
TRIG : TP200/SS-95 board (SV REF signal)
<TC-104 board, side A>
4
TP400
<SS-95 board, side A>
A
B
C
D
1
TP200
3
2
1
A
B
E
F
G
H
J
K
L
Preparation
M
N
P
SRW-5000/5500