7-2-9. PB Equalizer Adjustment
m
. This adjustment is required in both the 59.94 Hz mode
and the 50 Hz mode.
Adjust in the 59.94 Hz mode, and then adjust in the 50
Hz mode.
. When this adjustment is not finished normally, perform
"6-2. Video Tracking Check".
1. HDCAM SR Format
Tools
. Alignment tape:
HR5-1B
. Recording tape:
BCT-SR series
1. Activate the ALT MAINTENANCE menu, and
display the RF ADJUST menu.
(HOME menu → [SFT] + [DIAG] → [SFT] + [F8]
→ [ALT] → [F7] → RF ADJUST menu)
(For the RF ADJUST menu, refer to Section 3-4-5.)
2. Press the [F1] (FMT SEL) key several times to select
the HDCAM SR.
3. Press the [F4] (EQULZR ADJ) key to display the
EQUALIZER ADJUST menu.
4. Insert the alignment tape HR5-1B, then rewind it to the
tape beginning.
5. To execute the automatic adjustments, press the [F6]
(ALL CH ADJ) key then press the [SET] key.
. After 12 minutes, the adjustments are completed,
then the message [Complete] is displayed.
Saving the Data
n
Do not save the adjustment data if any automatic adjust-
ment was not completed properly.
6. Press the [F1] (NVRAM CTL) key to display the NV-
RAM CONTROL menu.
7. Select the "SAVE ALL DATA" by pressing the cursor
keys, then press the [F10] (EXIT) key to saving data.
. The message "Save Complete" will be displayed
when this data save is completed normally.
8. Eject the alignment tape.
9. Perform the next adjustment "2. HDCAM Format".
7-8
2. HDCAM Format
Alignment tape:
HR5-1A
1. Press the [F2] (FMT SEL) key several times to select
the HDCAM.
2. Insert the alignment tape HR5-1A, then rewind it to
the tape beginning.
3. To execute the automatic adjustments, press the [F6]
(ALL CH ADJ) key then press the [SET] key.
. After 2 minutes, the adjustments are completed, then
the message [Complete] is displayed.
Saving the Data
n
Do not save the adjustment data if any automatic adjust-
ment was not completed properly.
4. Press the [F1] (NVRAM CTL) key to display the NV-
RAM CONTROL menu.
5. Select the "SAVE ALL DATA" by pressing the cursor
keys, then press the [F10] (EXIT) key to saving data.
. The message "Save Complete" will be displayed
when this data save is completed normally.
6. Eject the alignment tape.
7. In case of the option HKSR-5002 installed model,
perform the next adjustment "3. Digital BETACAM
Format".
In case of the option HKSR-5002 is not installed, exit
the maintenance mode and perform "4. Adjustment in
the 50 Hz Mode".
SRW-5000/5500