2. CUE Output Level Adjustment
1. Be sure that TP101/CUE-13 (D-1) and E100/CUE-13
(C-1) are short-circuited.
2. Connect the audio analyzer to CUE OUT connector of
the connector panel.
3. Set the audio analyzer as follows:
Measuring mode: LEVEL, dBu
Input filter:
80 kHz LPF
4. Play back the portion of 1 kHz, +4 dBu of the align-
ment tape.
5. Check level using the audio analyzer, and then adjust
it.
1RV104/CUE-13 (B-1)
Adjusting point:
+4.0 ± 0.2 dBu
Specification:
6. Remove the shorting clip which is attached to TP101/
CUE-13 (D-1) and E100/CUE-13 (C-1).
3. CUE PB VCA Adjustment
1. Connect the audio analyzer to CUE OUT connector of
the connector panel.
2. Set the audio analyzer as follows:
Measuring mode: LEVEL, dBu
Input Filter:
80 kHz LPF
3. Play back the portion of 1kHz, +4 dBu of the align-
ment tape.
4. Check audio level using the audio analyzer, and then
adjust it.
1RV102/CUE-13 (D-1)
Adjusting point:
+4.0 ± 0.2 dBu
Specification:
1
A
B
RV101
TP100
C
E100
S100
TP101
RV100
RV102
D
CN100
CUE-13 Board (Side A)
7-18
2
RV106
TP105
TP104
TP103
S101
RV105
RV104
TP102
TP301
TP300
E103
RV103
4. CUE PB Frequency Response adjustment
1. Connect the audio analyzer to CUE OUT connector of
the connector panel.
2. Set the audio analyzer as follows:
Measuring mode: LEVEL, dBu
Input Filter:
80 kHz LPF
3. Play back the portion of 90 Hz to 12 kHz of the
alignment tape.
4. Check this PB level using the audio analyzer, and then
adjust it.
1RV203/AE-31H (D-2)
Adjusting point:
Specification:
Each frequency (3 kHz, 7 kHz, 10
kHz, 12 kHz) level:
1 kHz level ± 0.8 dB
Firstry, adjust the level of 10 kHz
until it equates with the level of 1
kHz. Then check each level of
other frequency.
LV400
TP401
E500
TP200
TP201
TP500
RV200
S200
E100
T500
RV203
RV201
RV202
S100
RV100
RV103
RV101 RV102
RV500
F
E
D
AE-31H Board (Side A)
LV600
6
TP601
E600
RV400
5
RV401
TP300
4
RV300
TP400
RV701
RV204
3
TP202
RV703
RV205
RV700
2
TP100
RV702
C
B
A
1
SRW-5000/5500