Hands Free Time-Out

The Scan Stand and Presentation Modes are referred to as "hands free" modes. If the scanner's trigger is pulled when using a
hands free mode, the scanner changes to manual trigger mode. You can set the time the scanner should remain in manual trig-
ger mode by setting the Hands Free Time-Out. Once the time-out value is reached, (if there have been no further trigger pulls)
the scanner reverts to the original hands free mode.
Scan the Hands Free Time-Out bar code, then scan the time-out duration (from 0-300,000 milliseconds) from the inside back
cover, and Save. Default = 5,000 ms.

Reread Delay

This sets the time period before the scanner can read the same bar code a second time. Setting a reread delay protects against
accidental rereads of the same bar code. Longer delays are effective in minimizing accidental rereads. Use shorter delays in
applications where repetitive bar code scanning is required. Reread Delay only works when in a
4-7). Default = Medium.
Short (500 ms)
Long (1000 ms)

User-Specified Reread Delay

If you want to set your own length for the reread delay, scan the bar code below, then set the delay (from 0-30,000 millisec-
onds) by scanning digits from the inside back cover, then scanning Save.
4 - 12
Hands Free Time-Out
User-Specified Reread Delay
Presentation Mode
(see page
* Medium (750 ms)
Extra Long (2000 ms)