User Guide
Removal (Water Cooling Kit)
Remove the water cooling kit from the CPU in the reverse procedure of the installation.
If you have installed or removed the water-cooling heat sink kit,
you must update the system.
Use the "Update CD-ROM" provided with N8101-339 water-
cooling heat sink to update the system.
Updating system is required in the following cases:
■
When the standard heat sink is replaced with water-cooling
heat sink
■
When the water-cooling heat sink is replaced with standard
heat sink
■
When 1-CPU configuration with water-cooling heat sink is
changed to 2-CPU configuration with water-cooling heat sink
■
When 2-CPU configuration with water-cooling heat sink is
changed to 1-CPU configuration with water-cooling heat sink
Caution
169