free hit counter
Dacor DYRTP366 Installation Instructions Manual

Dacor DYRTP366 Installation Instructions Manual

Discovery rangetop
Hide thumbs Also See for DYRTP366:

Advertisement

Installation Instructions
Discover y
Rangetop
®
Models: DYRTP366, DYRTP486
THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST
EDITION OF ANSI Z21.1 STANDARD FOR HOUSEHOLD GAS APPLIANCES.
Part No. 108317 Rev. C

Advertisement

Table of Contents
loading

Summary of Contents for Dacor DYRTP366

  • Page 1 Installation Instructions Discover y Rangetop ® Models: DYRTP366, DYRTP486 THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21.1 STANDARD FOR HOUSEHOLD GAS APPLIANCES. Part No. 108317 Rev. C...
  • Page 2: Table Of Contents

    To minimize exposure to these substances, always operate this unit according to the use and care manual, ensuring you provide good ventilation when cooking with gas. All specifications are subject to change without notice. Dacor assumes no liability for changes to specifications. © 2014 Dacor, all rights reserved.
  • Page 3: Important Safety Instructions

    • Always contact the Dacor Customer Service Team vicinity of this or any other appliance. about problems and conditions that you don’t under- WHAT TO DO IF YOU SMELL GAS stand.
  • Page 4: General Safety Precautions

    Do not allow pot holders to touch hot surfaces use Dacor backguard model AEB3609 (for model or gas burners. DYRTP366) or AEB4809 (for model DYRTP486) or • Do not wear loose or hanging apparel while using a non-combustible material. See the latest version of the rangetop.
  • Page 5: Installation Requirements

    3/4” NPT gas inlet, connects to regulator from bottom or rear of unit, end is recessed 2” (5.1 cm) from chassis bottom WIDTH (A) SIDE VIEW DYRTP366 35 7/8” (91.1 cm) Product tolerances: ±1/16” (±1.6 mm) unless otherwise DYRTP486 47 7/8” (121.6 cm)
  • Page 6: Cabinet And Countertop Layout

    Cabinet and Countertop Layout • To reduce the risk of personal injury and to reduce accumulated smoke in the room, Dacor strongly rec- ommends installing a range hood or downdraft vent. A WARNING hood should project horizontally a minimum of five (5) inches beyond the face of the cabinets.
  • Page 7: Cabinet/Cutout Dimensions

    Cabinet/Countertop Dimensions - Front View 13” (33.0 cm) max. Rangetop Model 36” (91.4 cm)* DYRTP366 36” (91.4 cm) 42” (106.7 cm)** 48” (121.9 cm)* DYRTP486 48” (121.9 cm) 54” (137.2 cm)** * Minimum ** Recommended See note 2 30”...
  • Page 8 D - Hole E - Downdraft Approved Downdraft Model Width Offset Vent Cutout Vent Models 36” 16 5/8” 33 1/2” ERV36, ERV3615, DYRTP366 (91.4 cm) (42.2 cm) (85.1 cm) PRV36 48” 20 13/16” 43 1/2” DYRTP486 ERV48, PRV48 (121.9 cm) (52.9 cm) (110.5 cm)
  • Page 9 Cabinet/Countertop Cutout Dimensions with Downdraft vent - Top View 3/8” min. (1.0 cm) flat countertop overhang required behind cutout Countertop Stiffener DYRTP366 or DYRTP486 rangetop 3/8” min. (1.0 cm) space behind Control panel downdraft vent overhang...
  • Page 10: Installation Instructions

    2 SimmerSear burner heads (2) provided hold-down bolts and washers provided. Do • 4 standard knobs not overtighten the bolts. • 2 MAX GRIDDLE knobs • Dacor Stainless Steel Cleaner • WOK ring • Griddle • 2 hold down bolts •...
  • Page 11: Gas Line Connection

    Installation Instructions Gas Line Connection WARNING • Verify that the gas supply meets specifications before connection. See page 3. • The maximum gas supply pressure to the regulator must never exceed 1/2 pounds per square inch (psi) or 3.5 kPa. •...
  • Page 12: Burner Component Installation

    Installation Instructions Burner Component Installation WARNING • Never attempt to operate the rangetop with any of the burner parts removed. • Do not attempt to adjust the burner air mixture set- tings. All adjustments are preset at the factory. • Remove the burner parts and grates from their shipping packages.
  • Page 13: Burner Knob Installation

    Installation Instructions Burner Knob Installation CAUTION Installing the rangetop knobs in the wrong position may result in damage to the rangetop griddle. The knobs for the center burners are marked with the maximum griddle settings. There are two (2) different types of knobs supplied with the rangetop.
  • Page 14: Verifying Proper Operation

    2. Connect the power the inside cover for location. cord to the electrical outlet. Dacor is not responsible for the cost of correcting problems 3. Turn on power to the electrical outlet at the circuit caused by a faulty installation.
  • Page 15: Installation Checklist

    • Proper installation is the responsibility of the home- owner. The importance of proper installation of your Dacor rangetop cannot be overemphasized. □ Is the electrical outlet for the rangetop grounded and located according to these instructions and in accor- dance with all applicable electrical codes? See pages 3 and 4.
  • Page 16: Wiring Diagram

    Wiring Diagram BLACK WHITE...
  • Page 17: Notes

    Notes...
  • Page 18 Notes...
  • Page 20 Dacor ● 14425 Clark Avenue, City of Industry, CA 91745 ● Phone: (800) 793-0093 ● Fax: (626) 403-3130 ● www.dacor.com...

This manual is also suitable for:

Dyrtp486

Table of Contents