Table 5-3. POST Error Codes and Messages (continued)
Error Code and Message
0B7C
The error occurred
during the redundant
power module
confirmation
0B7D
The normal
operation can not be
guaranteed with use
of only one PSU.
0B80
BMC Memory Test
Failed.
0B81
BMC Firmware Code
Area CRC check
failed.
0B82
BMC core hardware
failure.
0B90
BMC Platform
Information Area
Corrupted.
0B93
BMC SDR
Repository empty.
0B95
BMC FRU device
failure.
0B96
BMC SDR
Repository failure.
0BB0
SMBIOS - SROM
data read error
0BB1
SMBIOS - SROM
data checksum bad
0BC0
POST detected
startup failure of
CPU #1.
0BC1
POST detected
startup failure of
CPU #2.
0BC2
POST detected
startup failure of
CPU #3.
0BC3
POST detected
startup failure of
CPU #4.
Description
An error occurred while redundant
power supply was configured.
System is running on only one
power supply.
BMC SRAM test error
CRC error occurred in BMC code
area.
A firmware task cannot be ready
due to BMC hardware error.
The platform information area of
BMC is damaged.
No BMC SDR data exists.
Access to SROM that contains the
chassis information failed.
Access to FMEM sector that
contains SDR information failed.
Read error of SROM data
Checksum for the SROM data is
incorrect.
CPU #1 failed to startup.
CPU #2 failed to startup.
CPU #3 failed to startup.
CPU #4 failed to startup.
Action
Contact your service representative to
replace the power unit.
Contact your service representative to
replace the power unit.
Contact your service representative to
replace the I/O riser board.
Contact your service representative to
replace the baseboard.
Contact your service representative to
replace the riser card.
Contact your service representative.
Contact your service representative to
replace the failed CPU.
Problem Solving 5-17