Installation and Appliance Setup - Care and Operation
INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Call your dealer for questions on Installation, Operation, or Service.
NOTICE: SAVE THESE INSTRUCTIONS
Model(s):
Oakleaf Wood Stove
Wood Stove
Use & Care Video
!
Tested and approved for use with dry, seasoned cordwood
only. Do Not Burn Wet or Green Wood. Burning any other
type of fuel will void your warranty.
!
Check building codes prior to installation.
• Installation MUST comply with local, regional, state
and national codes and regulations.
• Contact local building or fire officials about restrictions
and installation inspection requirements in your area.
www.harmanstoves.com
Owner's Manual
CAUTION
CAUTION
Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15
!
Please read this entire manual before
installation and use of this wood-burning
room heater.
Failure to follow these instructions could
result in property damage, bodily injury
or even death.
• Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
• Do not overfire - If any external part starts to glow, you
are overfiring. Close air controls. Overfiring will void
your warranty.
• Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause a house fire.
!
HOT SURFACES!
Glass and other surfaces are hot during
operation and cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
stove.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other
flammable materials.
• Keep clothing, furniture, draperies and other flammable
materials away.
NOTICE
To obtain a French translation of this manual, please
contact your dealer or visit www.harmanstoves.com.
Pour obtenir une traduction française de ce manuel, s'il
vous plaît contacter votre revendeur ou visitez www.
harmanstoves.com.
WARNING
WARNING
3-90-798

Advertisement

Table of Contents
loading

Summary of Contents for Harman Oakleaf

  • Page 1 To obtain a French translation of this manual, please Check building codes prior to installation. contact your dealer or visit www.harmanstoves.com. • Installation MUST comply with local, regional, state and national codes and regulations. Pour obtenir une traduction française de ce manuel, s’il vous plaît contacter votre revendeur ou visitez www. • Contact local building or fire officials about restrictions harmanstoves.com. and installation inspection requirements in your area. www.harmanstoves.com Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 3-90-798...
  • Page 2 Floor protection must be a minimum 3/8” (9.5mm) of 0.84k material, or EPA Certified Emissions: 2.2 g/hr Facultatif Blower Harman # 1-00-797032: Note électrique 115 VAC, 60Hz, 1AMP maximum 0.45R. Must also be placed under any horizontal sections of flue connector, Fuel Type: Cord Wood Route cordon électrique de l'appareil.
  • Page 3: Table Of Contents

    E. Before Your First Fire ......26 F. Building and Maintaining a Fire ....26 3-90-798 Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 4: Listing And Code Approvals

    C. Glass Specifications This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass if needed. D. Electrical Rating Optional Blower: 115 VAC, 60 Hz. <1 Amps Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 3-90-798...
  • Page 5: Special Warnings And Notes

    NEVER CONNECT THIS UNIT TO A CHIMNEY FLUE The Oakleaf is a natural draft system which relies on SERVING ANOTHER APPLIANCE. a properly designed chimney to remove CO and other combustion by-products from the stove.
  • Page 6: Getting Started

    Do NOT connect to any forced air distribution duct FIRE HAZARD or system. DO NOT OPERATE APPLIANCE BEFORE READING AND UNDERSTANDING THE OPERATING INSTRUCTIONS. FAILURE TO OPERATE PROPERLY MAY CAUSE A HOUSE FIRE. Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 3-90-798...
  • Page 7: Component Locator

    Front Load Door Air Control Front Load Ash Door Door Latch Ash Door Level Latch adjuster D. Flue Direction Conversion The Oakleaf features an adjustable flue collar for rear or top exit. Follow these instructions for changing the direction. First, remove the upper rear heat shield by removing 8 Tek screws that secure it. Reaching upward through the firebox and the open bypass damper, loosen the retainer bolts on each of the flue collar and the cast iron plate. With the bolts loosened, turn the retainer to allow the piece to come free of the stove body. Reposition the flue collar and the cast iron plate and secure them with the retainers by tightening the bolts. You will now need to install a different upper rear heat shield. (See Section 7E). 3-90-798 Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 8: Pre-Use Checklist

    DO NOT OVERFIRE. 13. A properly grounded electrical receptacle is OR ANY SUCH ACTION THAT MAY CAUSE A FIRE HAZARD. available within reach of the blower's power cord (if installed). There are two brick clips located in the Owner’s manual bag. With the bricks in place, install the clips in the front corners as shown. The long portion of the clip will fit between the brick and the wall of the stove, with the short hook over-hanging to the inside of the firebox. Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 3-90-798...
  • Page 9: Dimensions & Clearances

    When configured for rear flue; Floor to center of flue measures 23-1/2" (597mm) NOTICE: When using rear flue configuration, a new upper rear heat shield, #1-00-797066 must be installed in place of the existing shield. 3-90-798 Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 10: Clearances To Combustibles

    Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel–Burning Appliances" for clearance from the top of the unit to ceiling. This unit was not tested for installation into an Alcove. Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel– Burning Appliances". Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 3-90-798...
  • Page 11 Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel–Burning Appliances" for clearance from the top of the unit to ceiling. This unit was not tested for installation into an Alcove. Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel– Burning Appliances". 3-90-798 Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 12: Floor Protection

    Minimum size floor protection for a corner installation hearth Type II floor protection must be used. pad is 43-3/8" x 32-5/16" (USA ONLY). NOTE: Floor protector *Floor protection for the front and sides as measured from WILL NOT touch the wall. the appliance door opening. Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 3-90-798...
  • Page 13: Chimneys And Venting

    The Harman Oakleaf may be installed with a minimum is illustrated on the next page. For details on the other three (.6mm) 24 gauge chimney connector pipe. The size of the options, refer to the most recent edition of the NFPA 211 code. connector should correspond to the size of the flue collar opening. Do not use makeshift compromises. No part of the chimney connector may pass through an attic or roof space, closet or other concealed space, or through a floor or ceiling. Whenever possible, avoid passing the connector through a combustible wall; if you must, use an approved wall pass- through, described later in this section. 3-90-798 Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 14: The Chimney

    8" x 8" or 7" x 12" (200mm x Ridge 200mm, 180mm x 300mm) may be used. Codes require that solid-fuel chimneys extend 3 ft. (0.9m) above the highest point at which they exit from the roof. Then, the chimney must extend 2 ft. (0.6m) above the highest point within a 10 ft (3m) radius. Thus, the 3 foot, 2 foot, 10 foot rule: Chimney 3ft. - Above roof exit point THE 3-FOOT, 2-FOOT, 10 FOOT RULE 2ft. - Higher than anything within- 10ft. of the chimney. Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 3-90-798...
  • Page 15 For example, you can prove fatally poisonous. Proper ventilation and draft will might remove the damper, replacing it with a secure, airtight, prevent this from happening. If you smell smoke, thoroughly noncombustible seal (removable for inspection); this also ventilate your dwelling, and contact your dealer for service. satisfies the requirement that no room air must be allowed Other causes of poor ventilation or draft are icing, exhaust to enter the chimney. fans, a blocked outside air inlet, and room air starvation. If your stove is sluggish and you get occasional odor, check these possibilities and increase the air flow in your home. 3-90-798 Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 16: Factory Built Chimney

    Chimney Connector Chimney Connector The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a Floor or Ceiling. Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 3-90-798...
  • Page 17 *Floor protection in accordance with Solid Fuel Appliance Listing The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a Floor or Ceiling. 3-90-798 Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 18 Oakleaf Woodburning Stove Oakleaf to Flue Fireplace Conversion (Minimum NFPA 211 Liner Connection) Flue liner with required air space Stainlesssteel chimney connector must extend to flue liner Minimum 8” masonry thickness in front of smoke chamber Airtight insulated clean-out Use damper adapter or seal with...
  • Page 19 The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a Floor or Ceiling. 3-90-798 Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 20 ** Check with your local building codes for clearance. The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a Floor or Ceiling. Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 3-90-798...
  • Page 21: Mobile Home (Us Only)

    The bracket will slip over the top of the leveling adjuster. The installer will need to determine and obtain the properly sized lag bolts. 3-90-798 Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 22: Appliance Set-Up

    CAUTION NEVER DRAW OUTSIDE COMBUSTION AIR FROM: • WALL, FLOOR OR CEILING CAVITY. • ENCLOSED SPACE SUCH AS AN ATTIC OR GARAGE Outside Air Attachment Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 3-90-798...
  • Page 23: Optional Blower Kit

    Slide heat shield in from DO NOT RUN THE CORD UNDER OR IN FRONT OF the rear of the unit THE APPLIANCE. Install nuts once shield is in place 3-90-798 Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 24: Operating Instructions

    THE STOVE FOR HIGHER HEAT OUTPUT MAY CAUSE DAMAGE TO THE STOVE AND COULD RESULT IN A HOUSE FIRE. USE ONLY APPROVED FUELS AND FOLLOW ONLY THESE OPERATION GUIDELINES. Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 3-90-798...
  • Page 25: Combustion Process

    The glass used in your Oakleaf is manufactured to exact are occurring at once. standards to withstand the high heat of the fire, but like all Always be sure to provide adequate ventilation to the room glass, it must be treated with common sense and care. Never where the appliance is located, to prevent air starvation. abuse the glass by slamming the door shut or striking the In tight construction, consider installing outside air to the glass with a heavy object. If the glass is broken or damaged,...
  • Page 26: User Controls

    Sliding this lever allows you to vary the amount of air to Providing you have the charcoal bed described, close the the fire, creating a range of heat outputs. The lowest heat bypass damper by pulling the handle toward the front of the output setting is to the left, and the highest is to the right. stove. The notches are provided as a reference for your comfortable heat settings. Do not, under any circumstances, alter the configuration or operation of the air control lever. Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 3-90-798...
  • Page 27 Do not allow the ash pan to over-fill. Ash buildup you will notice a “hot” or unpleasant smell; this is just the between the ash pan and the bottom of the grate can cause paint going through the curing process, and will disappear the grate to overheat and wear out prematurely. after a few fires. 3-90-798 Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 28: Service & Maintenance

    Harman wood stoves. Use of chemical creosote removal products will void the warranty of the Firedome combustion system. Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 3-90-798...
  • Page 29: General Maintenance Procedures

    Door Frame WARNING DO NOT ABUSE GLASS BY STRIKING OR SLAMMING THE DOOR CLOSED. THIS TYPE OF BREAKAGE IS NOT COVERED BY THE PRODUCT WARRANTY. 3-90-798 Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 30 • Remove the two bolts that hold the blower in place. • Use a vacuum and/or brush to remove all dust and pet hair from the blower wheel. • Reinstall the blower and tighten the two bolts securely. 6. Chimney • Frequency: As necessary / Yearly • By: Qualified Service Technician / Chimney Sweep The entire chimney should be professionally cleaned at least once yearly. It is best to have this done at the end of the heating season to be sure all ash is removed. You'll also want to inspect the condition of the chimney prior to using the appliance, to be sure there are no bird or animal nests. Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 3-90-798...
  • Page 31: Reference Materials

    Oakleaf Woodburning Stove Reference Materials A. Wiring Diagram 3-90-798 Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 32: Service Parts List

    B. Service Parts List Oakleaf Service Parts Beginning Manufacturing Date: Sept 2010 Cast Iron Wood Stove Ending Manufacturing Date: Active 1-90-797000-1 (Black), ((Sept 2010 thru June 2011)--1-90-797000-2 (Charcoal), 1-90-797000-3 (Golden re)) Part number list on following page. 06/15...
  • Page 33: Service Parts

    Load Door Handle Kit 1-00-797067 Gasket-3/8 Round LD, Top Load Door 5 Ft 1-00-37525 Inside Plate-Left w/Gasket 1-10-797104 Gasket-1/4 Round PSA 15 Ft 1-00-2312 Oakleaf Package 3-40-797022 Gasket-1/4 Round PSA 15 FT 1-00-2312 Ramp Assembly w/Gsket 1-10-797109 Gasket-1/4 Round PSA 15 FT 1-00-2312...
  • Page 34: Service Parts

    Oakleaf Service Parts Beginning Manufacturing Date: Sept 2010 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor. . Provide model number and serial number when requesting service parts from your dealer or distributor.
  • Page 35: Warranty Policy

    Hearth & Home Technologies C. Warranty Policy LIMITED LIFETIME WARRANTY Hearth & Home Technologies, on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer. WARRANTY COVERAGE: HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance will be free from defects in materials and workmanship at the time of manufacture. After installation, if covered compo- nents manufactured by HHT are found to be defective in materials or workmanship during the applicable warranty period, HHT will, at its option, repair or replace the covered components. HHT, at its own discretion, may fully discharge all of its obligations under such warranties by replacing the product itself or refunding the verified purchase price of the product itself. The maximum amount recoverable under this warranty is limited to the purchase price of the product. This warranty is subject to conditions, exclusions and limitations as described below. WARRANTY PERIOD: Warranty coverage begins on the date of original purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent, authorized HHT dealer/ distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of product shipment from HHT, regardless of the installation or occupancy date. The warranty period for parts and labor for covered components is produced in the following table. The term “Limited Lifetime” in the table below is defined as: 20 years from the beginning date of warranty coverage for gas appliances, and 10 years from the beginning date of warranty coverage for wood, pellet, and coal appliances. These time periods reflect the minimum expected useful lives of the designated components under normal operating conditions. Warranty Period HHT Manufactured Appliances and Venting Components Covered Parts Labor Wood Pellet Coal Electric Venting Wood All parts and material except as...
  • Page 36 WARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT authorized dealers is available on the HHT branded websites. • This warranty is only valid while the HHT appliance remains at the site of original installation. • This warranty is only valid in the country in which the HHT authorized dealer or distributor that sold the appliance resides. • Contact your installing dealer for warranty service. If the installing dealer is unable to provide necessary parts, contact the nearest HHT authorized dealer or supplier. Additional service fees may apply if you are seeking warranty service from a dealer other than the dealer from whom you originally purchased the product. • Check with your dealer in advance for any costs to you when arranging a warranty call. Travel and shipping charges for parts are not covered by this warranty. WARRANTY EXCLUSIONS: This warranty does not cover the following: • Changes in surface finishes as a result of normal use. As a heating appliance, some changes in color of interior and exterior surface finishes may occur. This is not a flaw and is not covered under warranty. • Damage to printed, plated, or enameled surfaces caused by fingerprints, accidents, misuse, scratches, melted items, or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes. • Repair or replacement of parts that are subject to normal wear and tear during the warranty period. These parts include: paint, wood, pellet and coal gaskets, firebricks, grates, flame guides, batteries and the discoloration of glass. • Minor expansion, contraction, or movement of certain parts causing noise. These conditions are normal and com- plaints related to this noise are not covered by this warranty. • Damages resulting from: (1) failure to install, operate, or maintain the appliance in accordance with the installation instructions, operating instructions, and listing agent identification label furnished with the appliance; (2) failure to install the appliance in accordance with local building codes; (3) shipping or improper handling; (4) improper opera- tion, abuse, misuse, continued operation with damaged, corroded or failed components, accident, or improperly/ incorrectly performed repairs; (5) environmental conditions, inadequate ventilation, negative pressure, or drafting caused by tightly sealed constructions, insufficient make-up air supply, or handling devices such as exhaust fans or forced air furnaces or other such causes; (6) use of fuels other than those specified in the operating instructions; (7) installation or use of components not supplied with the appliance or any other components not expressly authorized and approved by HHT; (8) modification of the appliance not expressly authorized and approved by HHT in writing;...
  • Page 37 Oakleaf Woodburning Stove Service & Maintenance Log Date Of Service Performed By Description Of Service Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 3-90-798...
  • Page 38 • Leave this manual with a n d m a i n t e n a n c e these instructions for safe party responsible for use instructions included. installation and operation. and operation. Printed in U.S.A. www.harmanstoves.com Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 3-90-798...

Table of Contents