Configuring the Voice Settings
PSTN (LINE Port)
Cisco SPA232D Administration Guide
Field
Detect Polarity
Reversal
Detect PSTN Long
Silence
Detect VoIP Long
Silence
PSTN Long
Silence Duration
VoIP Long Silence
Duration
PSTN Silence
Threshold
Min CPC Duration
Description
Choose yes to enable or choose no to disable this feature.
If enabled, the ATA will disconnect both call legs when this
signal is detected during a gateway call. If it is a PSTN
gateway call, the first polarity reversal is ignored and the
second one triggers the disconnection. For VoIP gateway
call, the first polarity reversal triggers the disconnection.
Default setting: yes
Choose yes to enable or choose no to disable this feature.
If enabled, the ATA will disconnect both call legs when the
PSTN side has no voice activity for a duration longer than
the length specified in the Long Silence Duration
parameter during a gateway call.
Default setting: no
Choose yes to enable or choose no to disable this feature.
If enabled, the ATA will disconnect both call legs when the
VoIP side has no voice activity for a duration longer than
the length specified in the Long Silence Duration
parameter during a gateway call.
Default setting: no
This value is minimum length of PSTN silence (or
inactivity) in seconds to trigger a gateway call
disconnection if Detect Long Silence is enabled.
Default setting: 30
This value is minimum length of VoIP silence (or inactivity)
in seconds to trigger a gateway call disconnection if
Detect Long Silence is enabled.
Default setting: 30
This parameter adjusts the sensitivity of PSTN silence
detection. Choose from {very low, low, medium, high, very
high}. The higher the setting, the easier to detect silence
and hence easier to trigger a disconnection.
Default setting: medium
Specify the minimum duration of a low tip-and-ring
voltage (below 1V) for the Gateway to recognize it as a
CPC signal or PSTN line removal.
Default setting: 0.2
4
144