Chimney Breach Fireplace Conversion with Combustible Wall
Minimum clearance from chimney
connector to uprotected ceiling 15"
Listed or approved thimble assembly
Mantel and Trim Protection
Floor Protection*
Combustible Floor
* Floor protection in accordance with Solid Fuel Appliance Listing
** Check with your local building codes inspector for clearance.
The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a
Floor or Ceiling.
Save These Instructions
* Floor Protection in Accordance with Solid Fuel Appliance Listing
** Check with your local building codes for clearance.
Harman® • TL2.0 Owner's Manual_R20 • 2011 -___ • 09/15
1" Clearance for exterior chimney or
2" clearance for interior chimney and
2" clearance for NFPA 211 - type
approved thimbles
Combustible
Wall
Sheet
Rock
Flue liner with required
air space
Airtight
insulated
clean-out
Damper closed
and sealed with
non-combustible
material
Dry Seasoned Wood Only!
19