When the installation plate is directly
mounted on the wall
1. Securely fit the installation plate onto the wall by
screws with the upper and lower parts to hook
up the indoor unit.
2. To mount the installation plate on a concrete wall
with anchor bolts, use the anchor bolt holes as
illustrated in the below figue.
3. Install the installation plate horizontally in the wall.
CAUTION
When installing the installation plate with a
mounting screw, do not use the anchor bolt holis.
Otherwise, the unit may fall down and result in
personal injury and property damage.
Fig. 10-3-4
5 mm dia. hole
Clip anchor
(local parts)
Fig. 10-3-5
CAUTION
Failure to firmly install the unit may result in
personal injury and property damage it the
unit falls.
• In case of block, brick, concrete or similar type
walls, make 5 mm dia. holes in the wall.
• Insert clip anchors for the
NOTE :
• Secure four corners and lower parts of the
installation plate with 4 to 6 mounting screws to
install it.
Anchor bolt
Projection
15mm or less
7 Mounting screw
l
Ø4 × 25
mounting screws.
10-3-3. Electrical Work
1. The supply voltage must be the same as the
rated voltage of the air conditioner.
2. Prepare a power source for the exclusive use
with the air conditioner.
NOTE :
• Wire type : More than H07RN-F or 60245 IEC66
2
(1.5 mm
or more).
• This appliance can be connected to a mains
in either of the following to ways.
1. Connection to fixed wiring:
A switch or circuit breaker which disconnects
all poles and has a contact separation of
at least 3 mm must be incorporated in the
fixed wiring. An approved circuit breaker
or switches must be used.
2. Connection with power supply plug:
Attach power supply plug with power cord
and plug it into wall outlet. An approved
power supply cord and plug must be used.
NOTE :
• Perform wiring works so as to allow a general
wiring capacity.
10-3-4. Wiring Connection
How to connect the connecting cable
Wiring the connecting cable can be carried
out without removing the front panel.
1. Remove the air inlet grille. Open the air inlet grille
upward and pull it toward you.
2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (or as according to
local regulations/codes) into the pipe hole on the
wall.
4. Take out the connecting cable through the cable
slot on the rear panel so that it protrudes about
20 cm from the front.
5. Insert the connecting cable fully into the terminal
block and secure it tightly with screws.
6. Tightening torque: 1.2 N•m (0.12 kgf•m)
7. Secure the connecting cable with the cord clamp.
8. Fix the terminal cover, rear plate bushing and
air inlet grille on the indoor unit.
–
–
55
FILE NO. SVM-12051
CAUTION