12
en | Installation
5.2
Install Mount and Housing
1.
2.
3.
4.
5.
Color
Green
White
Black
Table 5.1: Pre-wired 24 VAC kits
Color
Green
Brown
Blue
Table 5.2: Other kits
6.
7.
2014.11 | 1.0 | F.01U.309.609
Prepare and secure the wall mount to the mounting surface as described in the LTC
9215/00 Installation Manual included in the Documentation Packet.
Note: If you plan to route cables out the back of the mount, ensure that the placement of
the mount allows space behind the mounting surface to route and connect wires.
For housings that are not pre-wired, connect all required cables to housing PCB and
camera (see Connecting cables in housing, page 14).
Position the housing above the mount and feed the protruding cables through the mount
as described in Pulling cables through mount, page 13.
Attach the housing to the mount using the two (2) 1/4-20 x 0.5 in. screws and washers
provided in the mounting kit. The spring washers must be used for a secure connection.
The outermost set of 1/4-20 threaded holes (2) are for mounting to the LTC 9215/00
mount, and the innermost 1/4-20 threaded holes (1) are for mounting to all other mounts
and pan/tilts.
Connect the power cable to an incoming power supply (use wire connectors inside a
junction box if necessary to prevent water ingress).
The wiring color coding for the kits is:
Connect the video/audio/alarm/PoE cables as required.
Tilt or swivel the mount where necessary.
Connection
Ground
24 VAC
24 VAC
Connection
Ground
AC Live (24 VAC / 230 VAC)
AC Neutral (24 VAC / 230 VAC)
Installation Manual
DINION Housing Kit