Incoming Power Wires - Bosch VKC 4075 Installation Manual

Table of Contents

Advertisement

DINION Housing Kit
6.4.2

Incoming power wires

The terminal block accepts wire ranging from 0.5 mm² to 2.5 mm² (20 AWG to 14 AWG). When
using larger wire sizes, splice to a smaller size wire at the terminal block end. The splice may
need to be enclosed in a junction box if it does not pass through the fittings.
1.
2.
Bosch Security Systems
Strip no less than 6 mm (0.25 in.) and no more than 8 mm (0.31 in.) of insulation away
from the power supply wires. Do not nick the wires.
Connect the incoming power wires to the AC input connectors (3) on the terminal block
as shown in the following figure:
G
L
N
Callout
Function
1
Power cable input to housing:
- G (green/yellow) Earth wire
- L (brown) power wire
- N (blue) power wire
2
Power input grounding post
3
AC power input terminal block connectors
4
AC power output to camera
5
12 VDC power output to camera
6
Fuse
L
G
L
N
AC INPUT
AC OUT
Installation Manual
Connecting cables in housing | en
x
N
DC12v OUT
2014.11 | 1.0 | F.01U.309.609