General Information
Fan Delay Off =
"Fan Delay Off" is the amount of time in minutes the fan will
continue to run at the end of a cooling cycle.
To access Fan Delay
1. Use Down
to select "Fan Delay".
2. Press Select
.
To alter fan settings
3. Use Down
to select either "Fan Delay On" or "Fan Delay
Off" and press Select
. The chosen option will begin to flash.
4. Press Up
or Down
5. Press Select
to confirm.
To exit Fan Delay use Up
Select
to confirm.
USB Communication
The 3000 series uses an advanced USB logging feature for system
logging and diagnostics. The controller outputs 36 separate data
points per second to either a USB flash disk or transmitted over USB
via TTY to a client PC. To prepare the unit for logging, first verify the
USB port is set to the proper configuration. See "USB Port" for
information on configuring the USB port.
Flash Mode:
Suitable for logging directly to a USB flash disk.
PC Link Mode:
Suitable for communicating directly with a PC via USB.
USB Communication (Flash)
The main control can host a wide range of flash disks up to a
maximum capacity of 8GB. After verifying the USB port is set to
"Flash", simply insert a flash disk in to the USB port located above
the grille. The flash disk activity light (located on the flash disk) will
begin flashing immediately as data is recorded to the drive. Data is
recorded in one second increments and is only limited by the capacity
of the flash disk.
The system will create a file named "uline.csv" on the flash disk. In
the event the file already exists, new data will automatically be
appended to the end of the existing file. The file is output in a comma
delineated text format and may be viewed in a wide variety of simple
text readers or spreadsheet programs.
For information on identifying each data point, see the
"Communication Data" table on page 20.
18
to change settings.
to select "Return to Menu" and press
USB Communication (PC Link)
Data can be transmitted directly to a client PC via a serial
connection. Verify the USB port is set to "PC Link". Use a Type A to
Type A male to male USB cable to connect the system to a
®
Windows
compatible PC. It is necessary to install communication
drivers to the client PC. Drivers may be downloaded at
u-lineservice.com. Establish a connection using a Telnet / TTY
terminal application. U-Line recommends PuTTY. PuTTY is available
for download at u-lineservice.com. Once the connection is
established, the controller will output a series of 36 data points in 1
second increments. For information on identifying each data point,
see the "Communication Data" table on page 20.
USB Port
Up
Down
The USB Port menu option allows the selection of a communication
mode. The 3000 Series can communicate either via TTY to a PC or
log diagnostic information directly to a USB flash disk.
ID
Communication
PC Link
PC TTY
Flash
USB Flash Drive
NOTE: Unit ships in PC link mode.
To alter communication settings
1. Use Down
to select the current setting and press Select
2. Press Up
or Down
3. Press Select
to confirm.
To exit "USB Port" use Up
Select
to confirm.
To access USB Port
1. Use Down
to select "USB Port".
2. Press Select
.
u-line.com
RETURN TO MENU
USB PORT
PC Link
USB
Grille
to change settings.
to select "Return to Menu" and press
Select
.