7-1. Outline of Air Conditioner Control
This is a fixed capacity type air conditioner, which uses
a AC motor for an indoor fan. The AC motor drive
circuit is mounted in the indoor unit. And electrical
parts which operate the compressor and the outdoor
fan motor, are mounted in the outdoor unit.
The air conditioner is mainly controlled by the indoor
unit controller. The controller operates the indoor fan
motor based upon commands transmitted by the
remote control and transfers the operation commands
to the outdoor unit controller.
The outdoor unit controller receives operation
commands from the indoor unit, and operates the
outdoor fan motor and the compressor.
(1) Role of indoor unit controller
The indoor unit controller receives the operation
commands from the remote control and executes
them.
• Temperature measurement at the air inlet of the
indoor heat exchanger by the indoor
temperature sensor
• Temperature setting of the indoor heat
exchanger by the heat exchanger sensor
• Louver motor control
• Indoor fan motor operation control
• LED display control
• Transferring of operation commands to the
outdoor unit
• Receiving of information of the operation status
and judging of the information or indication of
error
(2) Role of outdoor unit controller
The outdoor unit controller receives the operation
commands from the indoor controller and
executes them.
• Compressor operation
control
• Operation control of
outdoor fan motor
OPERATION
MODE
RAS-18UFHP Series
RAS-18UFP Series
RAS-24UFHP Series
RAS-24UFP Series
7. OPERATION DESCRIPTION
Operations according
to the commands
from the indoor unit
Cooling
Heat
UH
Fan only
Dry
rpm
1120
Air flow volume (m
/h)
3
830
rpm
−
Air flow v
olume (m
/h)
3
−
rpm
1210
Air flow volume (m
/h)
3
rpm
−
Air flow volume (m
/h)
−
3
• Turning off the compressor and outdoor fan
when the outdoor unit receives the shutdown
command
• Defrost control in heating operation
(Temperature measurement by the outdoor heat
exchanger and control for the four-way valve
and the outdoor fan motor) *Heat pump Model
only
7-1-1. Louver control
(1) Vertical air flow louver
Position of veritcal air flow louver is automatically
controlled according to the operation mode.
Besides, position of vertical air flow louver can be
arbitrarily set by pressing [FIX] button.
The louver position which is set by [FIX] button is
stored in the microcomputer, and the louver is
automatically set at the stored position for the next
operation.
(2) Swing
If [SWING] button is pressed when the indoor unit
is in operation, the vertical air flow louver starts
swinging. When [FIX] button is pressed, it stops
swinging.
7-1-2. Indoor fan control (AC Fan motor)
(1) The indoor fan is operated by the stepless speed
change AC motor.
(2) For air flow level, speed of the indoor fan motor is
controlled in five steps (LOW, LOW
and HIGH). If AUTO mode is selected, the fan
motor speed is automatically controlled by the
difference between the preset temperature and
the room temperature.
LOW
MED
Table 7-1-1
UH
H
M+
M
L+
H
M
H
M+
M
M+
M
1060
1030
970
950
800
770 720
700
−
1030
1120
1060
900
−
770
830
800
680
1090
1000
1170
1020
930
920
760
900
750
−
1000
1210
1170
1090
−
930
900
810
750
− 22 −
FILE NO. SVM-06006
, MED, MED
+
LOW+MED
=
+
2
MED+HIGH
=
+
2
FAN TAP
L
L+
L
L-
SUL/SL-
L
L-
UL
L+
L-
L
L+
L
L-
UL
820
800
650
600
580
450
−
820
800
650
−
600
580
450
860
850
700
690
650
490
480
660
−
860
850
700
690
−
660
650
490
480
+
SUL/SL-
SUL
600
500
410
320
−
600
−
410
640
540
350
440
−
640
−
440