RF1100E | Installation Instructions | 3.0
3.0 Setup
1. Carefully open the service door (Item 3 in Figure 4)
and insert the two AA batteries (supplied),
observing the correct polarity.
2. Select a mounting location (refer to Section 2.0
Installation Considerations on page 3).
3. Temporarily mount the unit so you can remove it
as needed.
3.1
Sensitivity Setting
1. If the front housing is attached, carefully open the
service door (Item 4 in Figure 5).
2. Enable the LEDs for test purposes by sliding the
LED ENABLE switch (Item 5 in Figure 5) in the
direction the arrow points (above the switch). An
orange flag protrudes from the side of the
RF1100E.
Figure 4: RF1100E Front Layout
9
8
7
EVENT
6
5
4
1 - Service door tamper switch
2 - AA batteries
3 - Service Door
4 - SW4 test mode pads
5 - SW3 sensitivity DIP switches
6 - Alarm LED
7 - Event LED
8 - LED enable switch (off position)
9 - Housing screw
4
Setup
Figure 5: Sensitivity switch
5
1 - SENS1
2 - Test pads
3 - SENS2
3. Determine the sensitivity setting for your
application from Table 1.
Table 1: RF1100E Sensitivity Settings
Sensitivity
Maximum
Medium
1
Low
Lowest
2
4. Use a small screwdriver to move the sensitivity
3
switches. Use the settings determined in Step 3.
5. Turn on any sources of noise (such as machinery,
office, or audio equipment) in the area.
6. Observe the green event LED (Item 7 in Figure 8)
for approximately 1 min. If the green LED flashes,
relocate the unit or reduce the sensitivity by
adjusting the sensitivity switch.
7. Repeat Steps 3 through 6 until you achieve the best
sensitivity level.
8. After setting the sensitivity, slide the LED enable
switch (Item 5 in Figure 5) to the OFF position.
Bosch Security Systems | 6/04 | 4998138687C
1
EVENT
4 - Service door
5 - LED enable switch
(shown in the OFF
position)
SENS1
SENS2
Approximate Range
OFF
OFF
7.6 m
ON
OFF
4.6 m
OFF
ON
3 m
ON
ON
1.5 m
2
3
4