MMB Messages
E76F0602
Physical disk #n Global hot spare assigned model=%m (PCIBox or IOU#n-Slot#n-Port#n,
Cascade#, %s)
Meaning:
A global hot spare of HDD was generated. %s is disk enclosure model name.
Corrective action:
No action is necessary.
Severity:
Info
E76F0700
Physical disk #n bad block table is full model=%m (PCIBox or IOU#n-Slot#n-Port#n, Cascade#, %s)
Meaning:
Bad block table of HDD exceeded it to capacity. %s is disk enclosure model name.
Corrective action:
Please replace HDD.
Severity:
Warning
E76F0800
Physical disk #n shielded model=%m (PCIBox or IOU#n-Slot#n-Port#n, Cascade#, %s)
Meaning:
The HDD is shielded state. %s is disk enclosure model name.
Corrective action:
Please replace HDD.
Severity:
Warning
E77E01XX
Logical drive #n partially degraded (PCIBox#n-Slot#n-Port#n, Cascade#)
Meaning:
The redundancy is kept though the logical drive did degradation.
XX is the logical drive number.
Corrective action:
When the rebuild is done, it is likely to restore it. Still, when the problem continues, it is necessary to
exchange the HDD.
Severity:
Warning
E77E02XX
Logical drive #n degraded (PCIBox#n-Slot#n-Port#n, Cascade#)
Meaning:
The logical drive did degradation and the redundancy was lost.
XX is the logical drive number.
Corrective action:
When the rebuild is done, it is likely to restore it. Still, when the problem continues, it is necessary to
exchange the HDD.
Severity:
Warning
E77E03XX
Logical drive #n failed (PCIBox#n-Slot#n-Port#n, Cascade#)
Meaning:
The logical drive#n broke down.
Corrective action:
It is likely to be able to recover without losing data. Please gather the survey material because a detailed
investigation is necessary for that and contact the repair chat channel.
Severity:
Warning
CA92344-0540-06
68