Main unit
4
Panel PCB assembly attachment
1. Attach the panel PCB assembly to board case A with the 4 screws (1 2, 2
each).
2. Attach board case A and the panel PCB assembly to the operation panel A
assembly with the 5 screws 3.
3. Connect the switch PCB assembly's lead wire 1, inverter lead wire
assembly 2, LCD cable 3, and touch panel's lead wire 4 to the panel
PCB assembly.
*Key point
• Be sure to lock the connectors after the touch panel's lead
wire and the LCD cable have been connected to the panel
PCB.
4. Connect the USB lead wire assembly A 5 and the panel lead wire
assembly A 6 to the panel PCB assembly.
1
2
3
Operation panel
Screw, Truss
0.29 – 0.49 N-m
M2X3
Color; Silver
Screw, Bind
M3X3
0.78 – 1.18 N-m
Color; Silver
Taptite, Bind B
0.39 – 0.78 N-m
M3X8
Color; Gold
Torque
Torque
3
Torque
1
2
1
3
3
4
2
3
6
5
3 - 5