SL1000
Level
SA
Description
Use Program 22-11 : DID Translation Number Conversion to specify for each Translation Table
Program
entry (800).
• The digits received by the system (eight maximum)
22
• The extension the system dials after translation (36 digits maximum)
• The name that should show on the dialed extension display when it rings (12 characters maximum)
• The Transfer Target - 1 and 2
If the Transfer Targets are busy or receive no answer, those calls are transferred to the final transfer destina-
tion (Program 22-10).
• Operation Mode
Use the following chart when entering and editing text for names. Press the key once for the first char-
acter, twice for the second character, etc. For example, to enter a C, press 2 three times.
When entering names in the procedures below, refer to this chart. Names can have up to 12 digits.
Use this keypad digit ...
Input Data
Item No.
01
2-248
Program 22 : Incoming Call Setup
22-11 : DID Translation Number Conversion
1
Enter characters: 1 @ [ ¥ ] ^ _ ` { | }
2
Enter characters: A-C, a-c, 2.
3
Enter characters: D-F, d-f, 3.
4
Enter characters: G-I, g-i, 4.
5
Enter characters: J-L, j-l, 5.
6
Enter characters: M-O, m-o, 6.
7
Enter characters: P-S, p-s, 7.
8
Enter characters: T-V, t-v, 8.
9
Enter characters: W-Z, w-z, 9.
0
Enter characters: 0 ! " # $ % & ' ( ) ô õ ú å ä æ ö ü α ε θ В
Enter characters:
*
#
# = Accepts an entry (only required if two letters on the same key are needed - ex :
TOM). Pressing # again = Space. (In system programming mode, use the right
arrow soft key instead to accept and/or add a space.)
Clear/Back
Clear the character entry one character at a time.
Flash
Clear all the entries from the point of the flashing cursor and to the right.
Conversion Table Number
Input Data
Received Number
This is the received DID digits.
Key for Entering Names
When you want to ...
+ , - . / : ; < = > ? π Σ σ Ω ∞ ¢ £
*
Description
Maximum eight digits
(0 ~ 9,
, #)
*
Á À Â Ã Å Æ Ç É Ê ì ó 0
001 ~ 800
Default
See Default Value
Program 22 : Incoming Call Setup
ISSUE 1.1