ISSUE 1.1
Program 80 : Basic Hardware Setup for System
Level
IN
Description
Use Program 80-11 : MFC Tone Receiver Setup to various data for the MFC signal detection.
Input Data
MFC Tone Receiver Type Number
Item No.
01
Detect Level
02
Start delay time
03
Min. detect level
04
Max. detect level
05
Twist level
06
S/N ratio
07
ON detect time
08
OFF detect time
Item
Name
01
Detect Level
02
Start delay time
03
Min. detect level
04
Max. detect level
05
Twist level
06
S/N ratio
Programming Manual
80-11 : MFC Tone Receiver Setup
Item
0 = 0 dBm ~ - 25 dBm
1 = - 5 dBm ~ - 30 dBm
2 = - 10 dBm ~ - 35 dBm
3 = - 15 dBm ~ - 40 dBm
4 = - 20 dBm ~ - 45 dBm
5 = - 25 dBm ~ - 50 dBm
6 = - 30 dBm ~ - 55 dBm
0 ~ 255 (0.25 step, 0 ms ~ 64 ms)
0 ~ 15
detect level 0 = - 10 dBm (0) ~ - 25 dBm (15)
detect level 1 = - 15 dBm (0) ~ - 30 dBm (15)
detect level 2 = - 20 dBm (0) ~ - 35 dBm (15)
detect level 3 = - 25 dBm (0) ~ - 40 dBm (15)
detect level 4 = - 30 dBm (0) ~ - 45 dBm (15)
detect level 5 = - 35 dBm (0) ~ - 50 dBm (15)
detect level 6 = - 40 dBm (0) ~ - 55 dBm (15)
0 ~ 15
detect level 0 = 0 dBm (0) ~ - 15 dBm (15)
detect level 1 = - 5 dBm (0) ~ - 20 dBm (15)
detect level 2 = - 10 dBm (0) ~ - 25 dBm (15)
detect level 3 = - 15 dBm (0) ~ - 30 dBm (15)
detect level 4 = - 20 dBm (0) ~ - 35 dBm (15)
detect level 5 = - 25 dBm (0) ~ - 40 dBm (15)
detect level 6 = - 30 dBm (0) ~ - 45 dBm (15)
0 ~ 9 (1 dB ~ 10 dB)
0 ~ 4 (- 5 step, 0 dB ~ - 20 dB)
1 ~ 255 (15 step, 30 ms ~ 3840 ms)
1 ~ 255 (15 step, 30 ms ~ 3840 ms)
Table 2-16 Default Table
Type 1
Type 2
0
0
0
0
15 (- 25 dBm)
15 (- 25 dBm)
0 (0 dBm)
0 (0 dBm)
9 (10 dBm)
9 (10 dBm)
2 (0 dBm)
2 (0 dBm)
1 = MFC Receiver for Extension
2 = MFC Receiver for Trunk
3 = Reserved
4 = Reserved
5 = Reserved
Input Data
Type 3
Type 4
0
0
0
0
15 (- 25 dBm)
15 (- 25 dBm)
0 (0 dBm)
0 (0 dBm)
9 (10 dBm)
9 (10 dBm)
2 (0 dBm)
2 (0 dBm)
SL1000
Program
80
Type 5
0
0
15 (- 25 dBm)
0 (0 dBm)
9 (10 dBm)
2 (0 dBm)
2-423