ISSUE 1.1
Item
Name
39
Receive Line Block recover min Time
40
Transmit Remove Ring Time
41
Transmit Clear Signal Send Time
42
Transmit Seizure Signal Time
43
Group A Response Time
44
Group A Tone Complete Time
45
Group B Response Time
46
Group B Tone Complete Time
47
Group C Response Time
48
Group C Tone Complete Time
49
Group I Signal Time
50
Group I Tone Complete Time
51
Group II Signal Time
Conditions
• After set from Program 81-13-01 to 42, the E1 unit will be reset.
Feature Cross Reference
None
Programming Manual
Input Data
1 ~ 255 (64 ms ~ 16320 ms)
0 ~ 255 (0 ms ~ 1020 ms)
1 ~ 255 (16 ms ~ 4080 ms)
1 ~ 255 (8 ms ~ 2040 ms)
1 ~ 32 (1 sec ~ 32 sec)
1 ~ 32 (1 sec ~ 32 sec)
1 ~ 32 (1 sec ~ 32 sec)
1 ~ 32 (1 sec ~ 32 sec)
1 ~ 32 (1 sec ~ 32 sec)
1 ~ 32 (1 sec ~ 32 sec)
1 ~ 32 (1 sec ~ 32 sec)
1 ~ 32 (1 sec ~ 32 sec)
1 ~ 32 (1 sec ~ 32 sec)
SL1000
Default
32 (2048 ms)
0 (0 ms)
63 (1008 ms)
100 (800 ms)
12 (12 sec)
12 (12 sec)
12 (12 sec)
12 (12 sec)
12 (12 sec)
12 (12 sec)
12 (12 sec)
12 (12 sec)
12 (12 sec)
2-439
Program
81