Configuring the Satellite nV Optical Shelf System
Configuring a Client Port
This task describes the configuration of a client port that adds controllers to the nV optical system.
Configuration for a Transponder Application
For the examples described in the
configuration adds the following controllers:
• client ports:
• trunk ports:
The DWDM port on the router connected to the client port must be configured with the same encapsulation
as the client port. For example, if the client port has 'port-mode otn' for OTN encapsulation, then the DWDM
port must have 'g709 enable' configured as follows:
configure
controller optics 100/2/0/1
port-mode otn
controller dwdm 0/0/0/0
g709 enable
This configuration creates the following additional controllers:
• controller otu4 100/2/0/1
• controller odu4 100/2/0/1
• controller optics 100/2/0/1
Alternatively, if the client port has 'port-mode ethernet' for ethernet encapsulation, then the DWDM port must
not have 'g709 enable' configured as follows:
configure
controller optics 100/2/0/1
port-mode ethernet
This configuration creates the following additional controller:
• controller hundredgigECtrlr 100/2/0/1
Configuration for a Muxponder Application
For the examples described in the
configuration adds the following controllers for a 10Gbps optical link:
• 10 client ports:
• trunk ports:
controller optics 100/2/0/1
controller optics 100/2/0/2
controller ODU4 100/2/0/2
controller OTU4 100/2/0/2
controller optics 100/3/0/1
controller optics 100/3/0/2
...
controller optics 100/3/0/10
controller optics 100/3/0/2
Cisco ASR 9000 Series Aggregation Services Router nV System Configuration Guide, Release 5.3.x
Provisioning an Optical Application, on page 117
Provisioning an Optical Application, on page 117
Configuring a Client Port
task, the transponder
task, the muxponder
121