Basic format for control data
The transmission of control data from the computer
starts with a STX signal, followed by the command, the
parameters, and lastly an ETX signal in that order. If there
are no parameters, then the parameter signal does not
need to be sent.
STX
C1 C2 C3
:
Start
3-character
(02h)
command (3 bytes)
Notes:
If multiple commands are transmitted, be sure to wait
IRU WKH UHVSRQVH IRU WKH ¿UVW FRPPDQG WR FRPH IURP WKLV
XQLW EHIRUH VHQGLQJ WKH QH[W FRPPDQG
If an incorrect command is sent by mistake, this unit will
send an "ER401" command back to the computer.
Consult an Authorized Service Center for detail
instructions on command usage.
With the power off, this display responds to PON
command only.
IR IN / IR OUT Terminals connection
Use a 3.5 mm stereo mini plug to connect from the REMOTE OUT of the First LCD Display to the REMOTE IN of the
Second LCD Display. The IR signal from the First LCD Display will be sent to the Second LCD Display.
At this time, IR of the Second LCD Display will not work.
It is possible to daisy-chained by repeating the above connection.
P1 P2 P3 P4
P5
ETX
Colon
Parameter(s)
(1 - 5 bytes)
First LCD Display
Command
Command Parameter Control details
PON
POF
AVL
AMT
IMS
End
(03h)
DAM
Second LCD Display
*
None
Power ON
None
Power OFF
***
Volume 000 - 100
0
Audio MUTE OFF
1
Audio MUTE ON
None
Input select (toggle)
AV1
VIDEO IN input (VIDEO)
AV2
COMPONENT/RGB IN input
(Component)
HM1
HDMI1 input (HDMI1)
HM2
HDMI2 input (HDMI2)
DV1
DVI-D IN input (DVI)
PC1
PC IN input (PC)
DL1
',*,7$/ /,1. LQSXW
None
Screen mode select (toggle)
=220
=RRP
FULL
16:9
NORM
4:3
=20
=RRP
Third LCD Display
*
* Stereo mini plug (M3)
Connections
17