free hit counter
Harman Oakwood Wood Stove Owner's Manual
Harman Oakwood Wood Stove Owner's Manual

Harman Oakwood Wood Stove Owner's Manual

Installation and appliance setup - care and operation

Advertisement

Installation and Appliance Setup - Care and Operation
INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Call your dealer for questions on Installation, Operation, or Service.
NOTICE: SAVE THESE INSTRUCTIONS
Model(s):
Oakwood Wood Stove
Use & Care Video
!
Tested and approved for use with dry, seasoned cordwood
only. Do Not Burn Wet or Green Wood. Burning any other
type of fuel will void your warranty.
!
Check building codes prior to installation.
• Installation MUST comply with local, regional, state
and national codes and regulations.
• Contact local building or fire officials about restrictions
and installation inspection requirements in your area.
www.harmanstoves.com
Owner's Manual
Wood Stove
CAUTION
CAUTION
Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15
!
Please read this entire manual before
installation and use of this wood-burning
room heater.
Failure to follow these instructions could
result in property damage, bodily injury
or even death.
• Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
• Do not overfire - If any external part starts to glow, you
are overfiring. Close air controls. Overfiring will void
your warranty.
• Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause a house fire.
!
HOT SURFACES!
Glass and other surfaces are hot during
operation and cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
stove.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other
flammable materials.
• Keep clothing, furniture, draperies and other flammable
materials away.
NOTICE
To obtain a French translation of this manual, please
contact your dealer or visit www.harmanstoves.com.
Pour obtenir une traduction française de ce manuel, s'il
vous plaît contacter votre revendeur ou visitez www.
harmanstoves.com.
WARNING
WARNING
3-90-08327

Advertisement

Table of Contents
loading

Summary of Contents for Harman Oakwood Wood Stove

  • Page 1 To obtain a French translation of this manual, please Check building codes prior to installation. contact your dealer or visit www.harmanstoves.com. • Installation MUST comply with local, regional, state and national codes and regulations. Pour obtenir une traduction française de ce manuel, s’il vous plaît contacter votre revendeur ou visitez www. • Contact local building or fire officials about restrictions harmanstoves.com. and installation inspection requirements in your area. www.harmanstoves.com Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 2 DISTANCE AwAY FROM THE APPLIANCE ET AU MODE D’EMPLOI. GARDEZ LE MOBILIER ET LES AUTRES MATÉRIAUX COMBUSTIBLES BIEN À L’ÉCART DE L’APPAREIL. P.N. 3-90-249 Rev E Dry Seasoned Wood Only! Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 3: Table Of Contents

    E. Before Your First Fire ......26 F. Building and Maintaining a Fire ....26 3-90-08327 Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 4: Listing And Code Approvals

    8600 BTU’s which is the average BTU’s per Replace glass only with 5mm ceramic glass. Please contact pound of wood with an average moisture content of 20%. your dealer for replacement glass if needed. This wood heater needs periodic inspection and repair for proper operation. It is against federal regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual. Dry Seasoned Wood Only! Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 5: Special Warnings And Notes

    CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS TO START OR “FRESHEN UP” A FIRE IN THIS HEATER. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IT IS IN USE. 3-90-08327 Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 6: Getting Started

    Installation and service of this FAILURE TO OPERATE PROPERLY MAY appliance should be performed by CAUSE A HOUSE FIRE. qualified personnel. Hearth & Home Technologies recommends HHT Factory Trained or NFI Certified professionals. Dry Seasoned Wood Only! Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 7: Flue Direction Conversion

    Front Load Door Grate Andirons Front Load Door Latch Air Control Ash Door Ash Door Latch D. Flue Direction Conversion The Oakwood features an adjustable flue collar for rear or top exit. Follow these instructions for changing the direction. First, remove the upper rear heat shield by removing 8 Tek screws that secure it. Reaching upward through the firebox and the open bypass damper, loosen the retainer bolts on each of the flue collar and the cast iron plate. With the bolts loosened, turn the retainer to allow the piece to come free of the stove body. Reposition the flue collar and the cast iron plate and secure them with the retainers by tightening the bolts. You will now need to install a different upper rear heat shield. (See Section 7E). 3-90-08327 Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 8: Pre-Use Checklist

    • OPERATING APPLIANCE WITHOUT FULLY ASSEMBLING ALL COMPONENTS. • DO NOT OVERFIRE. OR ANY SUCH ACTION THAT MAY CAUSE A FIRE HAZARD. There are two brick clips located in the Owner’s manual bag. With the bricks in place, install the clips in the front corners as shown. The long portion of the clip will fit between the brick and the wall of the stove, with the short hook over-hanging to the inside of the firebox. Dry Seasoned Wood Only! Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 9: Dimensions & Clearances

    Oakwood Woodburning Stove Dimensions & Clearances A. Appliance Dimensions 24 15/16" 26 1/4" 18 1/16" 21" 30 1/4" 24.75” 3-90-08327 Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 10: Clearances To Combustibles

    Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel–Burning Appliances" for clearance from the top of the unit to ceiling. This unit was not tested for installation into an Alcove. Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel– Burning Appliances". Dry Seasoned Wood Only! Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 11 Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel–Burning Appliances" for clearance from the top of the unit to ceiling. This unit was not tested for installation into an Alcove. Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel– Burning Appliances". Dry Seasoned Wood Only! Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 12 Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel–Burning Appliances" for clearance from the top of the unit to ceiling. This unit was not tested for installation into an Alcove. Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel– Burning Appliances". 3-90-08327 Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 13 Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel–Burning Appliances" for clearance from the top of the unit to ceiling. This unit was not tested for installation into an Alcove. Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel– Burning Appliances". 3-90-08327 Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 14 (See above illustration.) Installing in front of a fireplace with Mantel Combustible Material Non-Combustible Fireplace 22” 559mm 16” 406mm 3-90-08327 Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 15: Floor Protection

    Minimum size floor protection for a corner installation hearth Type II floor protection must be used. pad is 54" x 54" (USA ONLY). NOTE: Floor protector WILL NOT *Floor protection for the front and sides as measured from touch the wall. the appliance door opening. Dry Seasoned Wood Only! Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 16: Chimneys And Venting

    The Harman Oakwood may be installed with a minimum is illustrated on the next page. For details on the other three (.6mm) 24 gauge chimney connector pipe. The size of the options, refer to the most recent edition of the NFPA 211 code. connector should correspond to the size of the flue collar opening. Do not use makeshift compromises. No part of the chimney connector may pass through an attic or roof space, closet or other concealed space, or through a floor or ceiling. Whenever possible, avoid passing the connector through a combustible wall; if you must, use an approved wall pass- through, described later in this section. 3-90-08327 Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 17: The Chimney

    2 Ft. (.6 m) Min 3 Ft. (.9 m) minimum Codes require that solid-fuel chimneys extend 3 ft. (0.9m) above exit point above the highest point at which they exit from the roof. Then, the chimney must extend 2 ft. (0.6m) above the highest point within a 10 ft (3m) radius. Thus, the 3 foot, 2 foot, 10 foot rule: Ridge 3ft. - Above roof exit point 2ft. - Higher than anything within- 10ft. of the chimney. Chimney THE 3-FOOT, 2-FOOT, 10 FOOT RULE Dry Seasoned Wood Only! Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 18 For example, you can prove fatally poisonous. Proper ventilation and draft will might remove the damper, replacing it with a secure, airtight, prevent this from happening. If you smell smoke, thoroughly noncombustible seal (removable for inspection); this also ventilate your dwelling, and contact your dealer for service. satisfies the requirement that no room air must be allowed Other causes of poor ventilation or draft are icing, exhaust to enter the chimney. fans, a blocked outside air inlet, and room air starvation. If your stove is sluggish and you get occasional odor, check these possibilities and increase the air flow in your home. 3-90-08327 Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 19: Factory Built Chimney

    Chimney Connector Chimney Connector The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a Floor or Ceiling. Dry Seasoned Wood Only! Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 20 *Floor protection in accordance with Solid Fuel Appliance Listing The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a Floor or Ceiling. 3-90-08327 Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 21 Use damper adapter or seal with non-combustible material Damper plate is removed or fastened in open position Floor Protection* Combustible Floor *Floor protection in accordance with solid fuel appliance listing Dry Seasoned Wood Only! Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 22 Damper plate is removed or fastened in open position. Use damper adapter or seal with non-combustible material. Floor Protection* Combustible Floor *Floor protection in accordance with solid fuel appliance listing 3-90-08327 Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 23 * Floor protection in accordance with Solid Fuel Appliance Listing ** Check with your local building codes for clearance. ** Check with your local building codes inspector for clearance. Dry Seasoned Wood Only! Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 24: Appliance Set-Up

    CAUTION NEVER DRAW OUTSIDE COMBUSTION AIR FROM: • WALL, FLOOR OR CEILING CAVITY. • ENCLOSED SPACE SUCH AS AN ATTIC OR GARAGE Outside Air Attachment Dry Seasoned Wood Only! Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 25: Optional Rear Vent Shield

    F. Optional Cozy Screen This appliance has been tested and approved for burning as an open fireplace. To do so, a spark screen (Harman part# 3-40-06960; Cozy Screen) must be installed over the front door opening. The by-pass damper must be kept in the open Top Vent position. The Cozy Screen can be used from the start of a fire or can be used with an existing one. When starting a fire with the Cozy Screen, smoke spillage may occur until it develops a draft strong enough to pull all smoke back into the flue. DO NOT LEAVE THE APPLIANCE UNATTENDED WITH THE DOOR OPEN! Load only small amounts of wood at a time. Rear Vent 3-90-08327 Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 26: Operating Instructions

    THE STOVE FOR HIGHER HEAT OUTPUT MAY CAUSE DAMAGE TO THE STOVE AND COULD RESULT IN A HOUSE FIRE. USE ONLY APPROVED FUELS AND FOLLOW ONLY THESE OPERATION GUIDELINES. Dry Seasoned Wood Only! Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 27: Combustion Process

    Do not tamper with or change the PRIMARY AIR FLOW SECONDARY AIR FLOW configuration of this grate system. PRIMARY & SECONDARY AIR FLOW 3-90-08327 Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 28: User Controls

    Sliding this lever allows you to vary the amount of air to stove. the fire, creating a range of heat outputs. The lowest heat output setting is to the left, and the highest is to the right. The notches are provided as a reference for your comfortable heat settings. Do not, under any circumstances, alter the configuration or operation of the air control lever. Dry Seasoned Wood Only! Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 29 Do not allow the ash pan to over-fill. Ash buildup you will notice a “hot” or unpleasant smell; this is just the between the ash pan and the bottom of the grate can cause paint going through the curing process, and will disappear the grate to overheat and wear out prematurely. after a few fires. 3-90-08327 Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 30: Service & Maintenance

    Harman wood stoves. Use of chemical creosote removal products will void the warranty of the Firedome combustion system. Dry Seasoned Wood Only! Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 31: General Maintenance Procedures

    WARNING DO NOT ABUSE GLASS BY STRIKING OR SLAMMING THE DOOR CLOSED. THIS TYPE OF BREAKAGE IS NOT COVERED BY THE PRODUCT WARRANTY. 3-90-08327 Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 Dry Seasoned Wood Only!
  • Page 32 This will keep any loosened material from falling into the Firedome Chimney combustion chamber. • Frequency: As necessary / Yearly • By: Qualified Service Technician / Chimney Sweep The entire chimney should be professionally cleaned at least once yearly. It is best to have this done at the end of the heating season to be sure all ash is removed. You'll also want to inspect the condition of the chimney prior to using the appliance, to be sure there are no bird or animal nests. Dry Seasoned Wood Only! Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 33: Reference Materials

    1-90-02490-5 (Honey Glo) (Ending Manufacturing Date: June 2009) -90-02490-15 (Enamel Sand) (Ending Manufacturing Date: June 2009) 1-90-02490-5 (Mojave Red) (Ending Manufacturing Date: June 2010) Part number list on following page. 06/15 www.harmanstoves.com Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 34: Service Parts

    Hardware Handle Assembly 2 Sets 1-00-00249 Handle and Plunger Kit 1-00-73765 Retainer Plate W/Hardware 1-00-249138 Inner Front Latch Kit 1-00-249143 Additional service part numbers appear on following page. www.harmanstoves.com Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 35 31.2 Back Heat Shield Kit - Rear Vent 1-00-02493 31.3 Outside Air Option 1-00-02494 31.4 Bottom Heat Shield Kit 1-00-02491 Additional service part numbers appear on following page. www.harmanstoves.com Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 36 Pkg of 100 3-30-3014-100 Washer, 1/4" Zinc Plated USS Flat Pkg of 100 3-30-0202-100 Washer, 5/16" Zinc Plated SAE Flat Pkg of 50 3-30-0205-50 Washer-D 5/16 Pkg of 4 3-30-0400311-4 www.harmanstoves.com Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 37: Warranty Policy

    Hearth & Home Technologies B. Warranty Policy LIMITED LIFETIME WARRANTY Hearth & Home Technologies, on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer. WARRANTY COVERAGE: HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance will be free from defects in materials and workmanship at the time of manufacture. After installation, if covered compo- nents manufactured by HHT are found to be defective in materials or workmanship during the applicable warranty period, HHT will, at its option, repair or replace the covered components. HHT, at its own discretion, may fully discharge all of its obligations under such warranties by replacing the product itself or refunding the verified purchase price of the product itself. The maximum amount recoverable under this warranty is limited to the purchase price of the product. This warranty is subject to conditions, exclusions and limitations as described below. WARRANTY PERIOD: Warranty coverage begins on the date of original purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent, authorized HHT dealer/ distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of product shipment from HHT, regardless of the installation or occupancy date. The warranty period for parts and labor for covered components is produced in the following table. The term “Limited Lifetime” in the table below is defined as: 20 years from the beginning date of warranty coverage for gas appliances, and 10 years from the beginning date of warranty coverage for wood, pellet, and coal appliances. These time periods reflect the minimum expected useful lives of the designated components under normal operating conditions. Warranty Period HHT Manufactured Appliances and Venting Components Covered Parts Labor Wood Pellet Coal Electric Venting Wood All parts and material except as...
  • Page 38 WARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT authorized dealers is available on the HHT branded websites. • This warranty is only valid while the HHT appliance remains at the site of original installation. • This warranty is only valid in the country in which the HHT authorized dealer or distributor that sold the appliance resides. • Contact your installing dealer for warranty service. If the installing dealer is unable to provide necessary parts, contact the nearest HHT authorized dealer or supplier. Additional service fees may apply if you are seeking warranty service from a dealer other than the dealer from whom you originally purchased the product. • Check with your dealer in advance for any costs to you when arranging a warranty call. Travel and shipping charges for parts are not covered by this warranty. WARRANTY EXCLUSIONS: This warranty does not cover the following: • Changes in surface finishes as a result of normal use. As a heating appliance, some changes in color of interior and exterior surface finishes may occur. This is not a flaw and is not covered under warranty. • Damage to printed, plated, or enameled surfaces caused by fingerprints, accidents, misuse, scratches, melted items, or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes. • Repair or replacement of parts that are subject to normal wear and tear during the warranty period. These parts include: paint, wood, pellet and coal gaskets, firebricks, grates, flame guides, batteries and the discoloration of glass. • Minor expansion, contraction, or movement of certain parts causing noise. These conditions are normal and com- plaints related to this noise are not covered by this warranty. • Damages resulting from: (1) failure to install, operate, or maintain the appliance in accordance with the installation instructions, operating instructions, and listing agent identification label furnished with the appliance; (2) failure to install the appliance in accordance with local building codes; (3) shipping or improper handling; (4) improper opera- tion, abuse, misuse, continued operation with damaged, corroded or failed components, accident, or improperly/ incorrectly performed repairs; (5) environmental conditions, inadequate ventilation, negative pressure, or drafting caused by tightly sealed constructions, insufficient make-up air supply, or handling devices such as exhaust fans or forced air furnaces or other such causes; (6) use of fuels other than those specified in the operating instructions; (7) installation or use of components not supplied with the appliance or any other components not expressly authorized and approved by HHT; (8) modification of the appliance not expressly authorized and approved by HHT in writing;...
  • Page 39: Dry Seasoned Wood Only

    Oakwood Woodburning Stove Service & Maintenance Log Date Of Service Performed By Description Of Service Dry Seasoned Wood Only! Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...
  • Page 40 • Leave this manual with a n d m a i n t e n a n c e these instructions for safe party responsible for use instructions included. installation and operation. and operation. Printed in U.S.A. www.harmanstoves.com Harman® • Oakwood Owner's Manual_R34 • 2004 -___ • 09/15 3-90-08327...

Table of Contents

Save PDF