Balluff BNI EIP-508-105-R015 User Manual

Balluff BNI EIP-508-105-R015 User Manual

Ethernet/ip ip67 modules
Hide thumbs Also See for BNI EIP-508-105-R015:
Table of Contents

Advertisement

BNI EIP-502-105-R015
BNI EIP-508-105-R015
EtherNet/IP™ IP67 modules
User's Guide

Advertisement

Table of Contents
loading

Summary of Contents for Balluff BNI EIP-508-105-R015

  • Page 1 BNI EIP-502-105-R015 BNI EIP-508-105-R015 EtherNet/IP™ IP67 modules User's Guide...
  • Page 2: Table Of Contents

    Cycle Settings Validation Settings Parameter Server Upload Flag on the IO-Link Device Configuration via Explicit Messages QuickConnect Rockwell Automation Products that are Compatible with QuickConnect Example with Rockwell Components PLC Program Fault State Enable/Disable Fault State Fault State Action www.balluff.com...
  • Page 3 Balluff Network Interface EtherNet/IP™, BNI EIP-50x-105-R015 IO-Link Device Parameterization Read IO-Link Parameter Write IO-Link Parameter Process Data 7.1. Process Data Inputs Standard Input Data IO-Link Input Data 7.2. Process Data Outputs Standard Output Data IO-Link Output Data Display 8.1. General 8.2.
  • Page 4: Notes

    Cross-references indicate where additional information on the topic is located. 1.4. Symbols This symbol indicates general notes. Note This symbol indicates a security notice which most be observed. 1.5. Abbreviations Balluff Network Interface Standard input port EtherNet/IP™ Electromagnetic compatibility Function ground Standard output port...
  • Page 5: Safety

    Before working on the device, switch off its power supply. Note In the interest of continuous improvement of the product, Balluff GmbH reserves the right to change the technical data of the product and the content of these instructions at any time without notice. www.balluff.com...
  • Page 6: First Steps

    First Steps 3.1. Module Overview Figure – Overview: BNI EIP-508-105-R015 Mounting hole Port 7 (IO-Link, standard I/O) EtherNet/IP™ port 2 Port 3 (IO-Link, standard I/O) Display Port 2 (IO-Link, standard I/O) Power supply, input Port 1 (IO-Link, standard I/O) Status LED: communication / module...
  • Page 7: Mechanical Connection

    Balluff Network Interface EtherNet/IP™, BNI EIP-50x-105-R015 First Steps 3.2. Mechanical Con- The module is secured by means of two M6 screws and two washers. nection Insulation support is available separately. 3.3. Electrical Con- nection Power Supply Function Description +24 V...
  • Page 8: I/O Port

    Unused I/O ports must be provided with cover caps to comply with degree of protection IP67. IO-Link Port M12, A-coded, female Function +24 V, 1.6 A Input/output 2 A IO-Link/input/output 2 A n.a. Port Port BNI EIP-502-105-R015 IN / OUT IN / OUT / IO-Link BNI EIP-508-105-R015 IN / OUT / IO-Link www.balluff.com...
  • Page 9: Technical Data

    Balluff Network Interface EtherNet/IP™, BNI EIP-50x-105-R015 Technical Data 4.1. Dimensions 4.2. Mechanical Data Housing material Plastic housing, resistant (Fortron 6165 A6 black) Enclosure rating per IEC 60529 IP 67 (only when plugged-in and threaded-in) Supply voltage 7/8" 4-pin, connector / female...
  • Page 10: Ethernet

    Module has no IP address Green, flashing Module has IP, but no connection established Net- Green Connection established work Red, flashing Connection timeout Red-green, flashing Initial sequence Bus clock: 10 Mbps Yellow Bus clock: 100 Mbps Green Data transfer www.balluff.com...
  • Page 11: Port

    Balluff Network Interface EtherNet/IP™, BNI EIP-50x-105-R015 Technical Data Port Each port has two bicolored LEDs for displaying the I/O statuses. Display Status Description I/O status The status of the input or output pins is 0 Yellow I/O status The status of the input or output pins is 1...
  • Page 12: Integration

    Integration Here you see an example of how the module can be integrated into a Rockwell RS Logix 5000: First go offline Right-click Ethernet (on the correct scanner card) Select a new module www.balluff.com...
  • Page 13 Balluff Network Interface EtherNet/IP™, BNI EIP-50x-105-R015 Integration Then select the general Ethernet module as the ETHERNET module in the communication path Now enter a user-defined tag name to select the general format Data-SINT, to enter the IP address of the module and to enter the correct connection parameters.
  • Page 14 Integration The new module and corresponding controller tags are generated automatically. Then download the configuration www.balluff.com...
  • Page 15 Balluff Network Interface EtherNet/IP™, BNI EIP-50x-105-R015 Integration When the download is done, you can observe and control the tags using the Controller Tags option. Make sure you select the correct tag name, which you configured beforehand. The input, output and configuration data for this is described on the following pages.
  • Page 16: Data Configuration

    BNI EIP-502-105-R015 Instance ID Data length INPUT OUTPUT CONFIG BNI EIP-508-105-R015 Instance ID Data length INPUT OUTPUT CONFIG 5.2. Configuration The following tables show an allocation of the configuration data sequence. The standard Data values specified below describe a configuration with the IO-Link function at Pin 4 and stand- ard I/O functions at Pin 2 and 4 of each port.
  • Page 17: Io-Link Port Configuration

    Balluff Network Interface EtherNet/IP™, BNI EIP-50x-105-R015 Integration IO-Link Port Con- BNI EIP-502-105-R015 and BNI EIP-508-105-R015 figuration Description Basic Time Cycle time Validation type 0 No validation Validation type 1 compatible (VID + DID) 2 Identical (VID + DID + SerNum)
  • Page 18: Validation Settings

    If the upload flag is set on the IO-Link device, an upload of the parameter data always takes place. If no upload flag is set and parameter data has already been stored, a download of the parameter data always takes place. www.balluff.com...
  • Page 19: Upload Flag On The Io-Link Device

    Balluff Network Interface EtherNet/IP™, BNI EIP-50x-105-R015 Integration Note After the upload of the parameter data, the vendor ID and device ID of the con- nected IO-Link device are also still saved until the data records are deleted. When the connected IO-Link device is started, a validation takes place. Thus, only an IO-Link device of the same type can be used for the data management.
  • Page 20: Configuration Via Explicit Messages

    10 (0x0A) 0: disabled 1: enabled(default) Overview of the QuickConnect classes and connection time: BNI EIP-50x-105-x015 HW 5 SW 3.2-3.4: QuickConnect Class B, connection time 1 second BNI EIP-50x-105-x015 HW 6 SW 3.5: QuickConnect Class B, connection time 450 milliseconds www.balluff.com...
  • Page 21: Rockwell Automation Products That Are Compatible With Quickconnect

    Balluff Network Interface EtherNet/IP™, BNI EIP-50x-105-R015 Configuration via Explicit Messages Rockwell Auto- mation Prod- ucts that are Compatible with QuickConnect Source: Allen-Bradley Ethernet/IP QuickConnect Application Technique Page 13 www.balluff.com...
  • Page 22: Example With Rockwell Components

    If needed, only one managed switch may be used between the PLC and Ethernet/IP slave.  To trigger the QuickConnect sequence, an electrical lock signal is required that reads in the supply voltage of the QuickConnect slaves via the controller. www.balluff.com...
  • Page 23: Plc Program

    Balluff Network Interface EtherNet/IP™, BNI EIP-50x-105-R015 Configuration via Explicit Messages PLC Program Source: Allen-Bradley Ethernet/IP QuickConnect Application Technique, Page 29 www.balluff.com...
  • Page 24 Configuration via Explicit Messages Source: Allen-Bradley Ethernet/IP QuickConnect Application Technique, Page 30 www.balluff.com...
  • Page 25 Balluff Network Interface EtherNet/IP™, BNI EIP-50x-105-R015 Configuration via Explicit Messages Source: Allen-Bradley Ethernet/IP QuickConnect Application Technique, Page 31 www.balluff.com...
  • Page 26: Fault State

    The fault state settings are stored only temporarily in the module. They are deleted after a power reset. To ensure a long-term fault state configuration, the configuration has to be pro- grammed via the PLC so that the settings are transferred to the module again when the system is restarted. www.balluff.com...
  • Page 27: Io-Link Device Parameterization

    Balluff Network Interface EtherNet/IP™, BNI EIP-50x-105-R015 Configuration via Explicit Messages IO-Link Device There are two options for configuring an IO-Link device connected to the IO-Link port. Parameteriza-  tion Configuration via the web server refer to the "Web Server" chapter under "Device Properties"...
  • Page 28 Destination Array (Read) shows the read-out value. In case of a configuration error, the error code is likewise displayed there. In the "Communication" window, you have to select the Ethernet module on which the configuration is to take place. www.balluff.com...
  • Page 29: Write Io-Link Parameter

    Balluff Network Interface EtherNet/IP™, BNI EIP-50x-105-R015 Configuration via Explicit Messages Write IO-Link Service Code Class Instance Attribute Parameter 0x32 0x96 1-4 / 1-8 (corresponds to IO-Link port 1-4 for 0x02 BNI EIP-502-105-R015 and IO-Link ports 1-8 for BNI EIP-508-105-R015 (Write Parame-...
  • Page 30: Process Data

    IO-Link port 6 Process data inputs at IO-Link port 6 344…391 IO-Link port 7 Process data inputs at IO-Link port 7 Standard Input BNI EIP-502-105-R015 and BNI EIP-508-105-R015 Data Description Input data  Input at port 0, pin 4 The result is 0 only if the port is configured as an IO-Link port.
  • Page 31: Io-Link Input Data

    Balluff Network Interface EtherNet/IP™, BNI EIP-50x-105-R015 Process Data IO-Link Input Data BNI EIP-502-105-R015 and BNI EIP-508-105-R015 Description … IO-Link port 0 input data IO-Link status IOL: Port in IO-Link mode DC: Device connected 0: Reserved IO-Link error VF: Validation failed...
  • Page 32: Process Data Outputs

    IO-Link port 6 Process data output at IO-Link port 6 230…261 IO-Link port 7 Process data output at IO-Link port 7 Standard Output BNI EIP-502-105-R015 and BNI EIP-508-105-R015 Data Byte Description Output data  Output at port 0, pin 4...
  • Page 33: Display

    Balluff Network Interface EtherNet/IP™, BNI EIP-50x-105-R015 Display With the implemented display, the address is output directly to the devices BNI EIP… 8.1. General The following address types are possible: • IP address • Subnet mask • Gateway address Each address is composed of 4 octets.
  • Page 34: Design And Symbols

    Condition: Briefly press the Set key Condition: Press and hold the Set key (at least 3 seconds)  Condition: Briefly press the arrow key 8.6. Startup B A L L U F F BALLUFF Module name EIP-508- 105-R015 VERSION Hardware and firmware update H W : 1 .
  • Page 35: Ip Setup

    Balluff Network Interface EtherNet/IP™, BNI EIP-50x-105-R015 Display 8.8. IP Setup X STATIC IP editing mode DHCP FACTORY SETTI N G STATIC STATIC X STATIC   DHCP X DHCP DHCP FACTORY SETTING X FACTORY SETTING FACTORY SETTING  Editing mode •...
  • Page 36: Module Information

    The plc lock function can also be used by setting a bit in the process data outputs. (see bit layout, standard output data) Note: You cannot select editing mode in the display if the plc lock is set in the process data inputs by a bit (see bit layout, standard output data) www.balluff.com...
  • Page 37: Web Server

    For connection setup with the web server, enter the IP address of the module in the address line of the browser. A welcome page appears with a list of Balluff Ethernet network interfac- Please use Internet Explorer 7 or higher.
  • Page 38: Home

    You can also see here whether the display lock was set via the control unit. The navigation bar appears in the upper area of the window, which allows you to switch between the various web pages. A click on the corresponding text is all it takes. www.balluff.com...
  • Page 39: Diagnostic Process

    Balluff Network Interface EtherNet/IP™, BNI EIP-50x-105-R015 Web Server 9.3. Diagnostic Pro- On this page you can read some information about the current process data of the module cess and the status shown by the corresponding LEDs. If an IO-Link device is connected to one of the configured IO-Link terminals, some of the device data will be displayed in addition to the module data.
  • Page 40: Device Properties

    You can monitor only the process data of the connected IO-Link device, but cannot set the output data. If the IO-Link device requires output data, you have to set it via the control unit us- ing the corresponding software. www.balluff.com...
  • Page 41 Balluff Network Interface EtherNet/IP™, BNI EIP-50x-105-R015 Web Server This figure shows you the "Parameter Data" options for the IO-Link device. In addition, it is possible to read and configure the parameters of the IO-Link device via the "Parameter Data" option.
  • Page 42: Diagnostic Module

    Web Server 9.5. Diagnostic Mod- The current status of the module and network appears on this page as shown on the mod- ule. The status is also discussed under "Description". www.balluff.com...
  • Page 43: Configurations

    Balluff Network Interface EtherNet/IP™, BNI EIP-50x-105-R015 Web Server 9.6. Configurations The configuration page permits configuration of the module. You can change the addresses set under DHCP Client and add your own module information texts as well as a description of the module.
  • Page 44: Appendix

    M4x6 screw • 20 informational signs 10.2. Order Number BNI EIP-50x-105-R015 Balluff Network Interface Ethernet IP Functions 502 = IP 67 IO-Link master module, 4 IO-Link ports 508 = IP 67 IO-Link master module, 8 IO-Link ports Versions 105 = display version, 2-port switch...
  • Page 45: Notes

    Notes www.balluff.com...