If the space is larger than the width of the
appliance, you must adjust the side
measurement.
3. Install the anti-tilt protection (A)
approximately 77 mm below the top surface
of the appliance and 50 mm from the left or
right side of the appliance into the circular
hole on the bracket. Screw it into the wall.
4. Check that the anti-tilt protection (A) fits
minimum 20 mm into the hole in the rear
wall of the appliance (B) when you push the
appliance.
Electrical installation
WARNING!
The manufacturer is not responsible
if you do not follow the safety
precautions from Safety chapters.
This appliance is supplied without a main plug
or a main cable.
Covering terminal board
Energy efficiency
Product information for hob according to EU 66/2014
Model identification
Type of hob
Number of cooking zones
Heating technology
26
• The recommended cross-section area is six
• When you refit the mains terminal cover,
• Make sure that the cover is securely
50 mm
77 mm
A
Terminal board
Make sure that the links are fitted as shown.
ZCI660MXC
Hob inside Freestanding Cooker
4
Induction
square millimetres (6 mm²).
make sure that the lower tabs are located
inside the bottom edge of the aperture,
before you fix the two screws into the top
edge of the mains terminal cover.
fastened.
To open the cover of terminal board
obey the procedure in opposite
sequence.
Do not remove blanking plates.
L
L
N
N
N
www.zanussi.com