EPSON WorkForce 600/EPSON Stylus OFFICE TX600FW/BX600FW/EPSON Stylus SX600FW/ME OFFICE 700FW
When installing the ASF Unit, be sure to align the dowels (x2)
of the Base Frame with the positioning holes (x2) of the ASF
Unit as shown in
Figure.
Tighten the screws in the order given in
When routing the PE Sensor cable, pay attention to the
following instructions.
•
Route the cable in the order given in
Make sure to attach the cable with the blue line facing toward
•
the Base Frame.
Figure 4-95. Routing PE Sensor Cable
Check that the cable is tightly routed and there is no slack in
•
it.
After replacing the ASF Unit, be sure to perform the required
A D J U S T M E N T
R E Q U I R E D
lubrication.
•
Chapter 6 " MAINTENANCE" (p.163)
DISASSEMBLY/ASSEMBLY
4-94.
Figure.
4-93.
Figure.
4-91.
PE Sensor Connector Cable
Disassembling the Printer Mechanism
4.5.17 Ink System Unit
Parts/Components need to be removed in advance
Scanner Unit/ADF Unit/Upper Housing /Hinge/Middle Cover/Printer Mechanism/
Card Slot Cover/Main Board Unit/Left Frame/Front Frame/Right Frame/CR
Motor/CR Scale/Hopper/Main Frame Assy/ASF Unit
Removal procedure
When disassembling/assembling the Ink System Unit, pay attention
C A U T I O N
to the following instructions.
Be cautious not to get injured with the sharp edges of the
Frame Support.
Figure 4-96. Sharp Edges of Frame Support
Do not touch or damage the Sealing Rubber or the Head
Cleaner.
Mark the connecting point before removing the Ink Tube.
Revision A
Frame Support
129
Confidential