free hit counter

Advertisement

IMPORTANT:
THESE INSTRUCTIONS ARE TO
REMAIN WITH THE HOMEOWNER
WARNING: If the information in this
manual is not followed exactly, a fi re or
explosion may result causing property
damage, personal injury or loss of life.
• Do not store or use gasoline or other
fl ammable vapors and liquids in the
vicinity of this or any other appliance.
• WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electrical switch;
do not use any phone in your
building.
- Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
- I f y o u c a n n o t r e a c h y o u r
gas supplier, call the fire
department.
• Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
161204-24
Broadway
Direct Vent Gas Insert
INSTALLATION
AND OPERATING
INSTRUCTIONS
Broadway-A
SERIES A
# 5055.6591

Advertisement

Table of Contents
loading

Summary of Contents for Pacific energy Broadway

  • Page 1 - I f y o u c a n n o t r e a c h y o u r gas supplier, call the fire department. • Installation and service must be performed by a qualified installer, Broadway service agency or the gas supplier. Direct Vent Gas Insert SERIES A INSTALLATION...
  • Page 2: Table Of Contents

    Contents Caution ................3 Safety ................3 Maintenance ..............3 Installation ................ 4 Clearances ............... 5 Venting ................6 Gas Supply ..............7 Remote Control Installation ..........8 Levelling Legs ..............9 Burner Removal ............... 9 Glass Frame ..............9 Removal/Installation ............
  • Page 3: Caution

    FOR YOUR SAFETY - Do not install or operate your Caution: Turn off gas and electrical power supply Pacific Energy Broadway Direct Vent Gas Insert and allow ample time for unit to cool before servicing without fi rst reading and understanding this manual. Any appliance.
  • Page 4: Installation

    Existing Fireplace (Masonry or Factory Built) The Broadway Direct Vent Gas Insert is designed to be installed into a masonry or a factory built zero clearance fi replace. The masonry fi replace must be...
  • Page 5: Clearances

    Clearances Fig. # 5 The minimum clearances from the appliance to combustible surfaces are shown on Fig. #4 and #5. Adequate clearances around air openings and air Mantel supplies are required. MINIMUM CLEARANCES TO COMBUSTIBLES: Adjacent sidewall: ....3.0 in. (76 mm) Ceiling to appliance: ....
  • Page 6: Venting

    Venting Fig # 7 Vent Terminal Caution: Only Flex Liner kit (MIND.FL25) or an approved Seal gas vent fl ue liner and a Vent Terminal (MIND.VTTERM) is approved for use with this appliance. Also approved for use is Simpson Dura-Vent GS termination kits, both Standard Vertical Termination cap (#980) and the Extended Vertical Termination cap (#930) in conjunction with the 3"...
  • Page 7: Gas Supply

    Fig # 9 Gas Supply Caution: The gas line should be installed by a qualifi ed service person in accordance with all building codes. Consult local and/or national building codes before proceeding. The gas valve is fi tted with a 90° street elbow for easy gas connectio.
  • Page 8: Remote Control Installation

    Remote Control Installation Caution: DO NOT connect the batteries to the remote control receiver until the all of the wires are connected to the gas valve as a short circuit could result in damage to the electrical components of the remote control. When installing the remote to the fi replace please refer to fi gures 10 and 11.
  • Page 9: Levelling Legs

    Glass Frame Levelling Legs Removal/Installation Levelling legs are provided as a convenient means for levelling the appliance when it is installed on Warning: Turn off the fi replace and allow ample time an irregular surface. The legs (3" long threaded to cool before proceeding.
  • Page 10: Brick Panel Installation

    Brick Panel Installation 1) Remove window (see page 9). 2) Remove the 2 screws securing the grate to the mounting brakets (Fig # 14). 3) Remove the 4 screws securing the fi rebox baffl e to the fi rebox roof (Fig # 15). 4) Place the fl oor panels on the fi rebox base (Fig # 16).
  • Page 11 Fig #16 Fig #17 Fig # 18 161204-24 # 5055.6591...
  • Page 12: Log Set Installation

    Log Set Installation The Ceramic logs are durable and long lasting when installed properly; However, they are delicate and may be damaged easily if not handled with care. Unpack and inspect log set. There should be a total of 7 logs and one ember bed. Gas and vent connections should be made before installing logs.
  • Page 13 Left Front Log Right Front Log Step 5: Step 6: Fig. # 19e Fig. # 19f Pt#: 5097.25 Pt#: 5097.26 The slot on the underside of the log locates on The slot on the underside of the log locates on the pin on the grate.
  • Page 14: Lighting Instructions

    Lighting Instructions FOR YOUR SAFETY READ BEFORE LIGHTING phone in your building. WARNING: If you do not follow these - Immediately call your gas supplier from a neigh- instructions exactly, a fire or explosion bour's phone. Follow the gas supplier's instruc- may result causing property damage, tions.
  • Page 15: Remote Operation

    3) Timer setting Remote Operation The third option is to program the fi replace to operate at The Broadway Direct Vent Insert comes equipped with set times. It has two "on and "off" cycles which allows a thermostatic remote control .
  • Page 16: Manual Operation

    Manual Operation First Fire When lit for the fi rst time, the appliance will emit a slight In the unlikely event of remote control failure, the fl ame can still be turned up and down using the fl ame odour for a couple of hours. This is due to the curing of adjustment knob located just above the "on/off"...
  • Page 17 Operation: Fig. # 26 The variable speed circulating air blower is thermostatically controlled for automatic operation, as well manually with a convenient bypass switch. Automatic: To operate the blower automatically, push the rocker switch to the "AUTO" position and set the fan speed control to desired setting. This will allow the blower to turn on automatically once the Insert has come up to operating temperature.
  • Page 18: Replacement Parts

    Replacement Parts See Fig. # 29 (WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION) ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO. 1.... FIREBOX BAFFLE ......... 9827 ....PANELS, BDWA 6 PC SET ..... 5098.7662 2.... GLASS w/GASKET ......GLAS.2069 10 ..PANEL, BDWA, LHS F/BOX ...... 5098.761 3....
  • Page 19: Surround Replacement Parts

    1.... PIANO HINGE ..........5070.2 ....BROADWAY TRIM, SET ......5091.0513 2.... SCREW, 8x1/2 PAN HD QUAD SMS, BLK ..5041 10 ..TRIM, BROADWAY, LHS ..... 5091.05111 3.... SCREW, 6x3/8 FLAT HD PHIL, BLK ..5042.5005 11 ..TRIM, BROADWAY, RHS ..... 5091.05112 4....
  • Page 20: Burner Replacement Parts

    Burner Replacement Parts See Fig. # 31 (WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION) ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO. 1.... BURNER MOUNTING BRACKET ..... 2811.01 8 .... ORIFICE #39D, NG ........5019.501 2.... CERAMIC SPACER ........2816 9 ....
  • Page 21: Direct Vent Terminal Kit

    Appendix A Direct Vent Terminal Kit MIND.VTTERM Please refer to the Installation Instructions provided with the appliance for proper installation. This box contains: 1..Vent Terminal 4..#10 x 5/8" TEKS Screws 6..#10 x 1 1/2" Machine Screws 250901 MIND-VTTERM 5055.658 161204-24 # 5055.6591...
  • Page 22: Vent Terminal Flashing Installation Guide

    Vent Terminal Flashing Installation Guide MIND.FLASH This kit contains: 1..Vent Terminal Flashing 4..#8 x 1" Sheet Metal Screws Installation: Attach the vent terminal to the Attach the fl ashing to the chimney, fl ashing using the 4 screws by fi rst notching and then bending the excess portion of the fl ashing downwards to suit the installation.
  • Page 23: Safety Label

    Mantel Side Supports to Appliance / Supports du manteau à l'Appareil : 3 in. / 3 po. (76 mm) PACIFIC ENERGY FIREPLACE PRODUCTS LTD. DO NOT REMOVE OR PO Box 1060, Duncan, British Columbia, V9L 3Y2 COVER THIS LABEL MADE IN CANADA / FABRIQUE AU CANADA 170704 5050.702...
  • Page 24 Pacifi c Energy Fireplace Products Ltd. 2975 Allenby Road, Duncan, BC V9L 6V8 Phone: 250-748-1184 Web site: http://www.pacifi cenergy.net 161204-24 Broadway-A # 5055.6591 Printed in Canada...

Table of Contents