Note: See "System" on page 116 to determine which components should be replaced by a field service technician.
Error code/symptom
166-400-000 System Management: Failed
(ISMP self test result failed tests: x where x
= Flash, RAM, or ROM.)
180-XXX-000 (Diagnostics LED failure)
180-XXX-001 (Failed front LED panel test)
180-XXX-002 (Failed diagnostics LED panel
test)
180-XXX-003 (Failed system board LED
test)
180-XXX-005 (Failed SCSI backplane LED
test)
180-361-003 (Failed fan LED test)
201-XXX-0nn (Failed memory test.)
201-XXX-999 (Multiple DIMM failure, see
error text)
202-XXX-001 (Failed system cache test)
202-XXX-002 (Failed system cache test)
206-XXX-000 (Failed diskette drive test)
215-XXX-000 (Failed IDE CD-ROM drive
test)
217-198-XXX (Could not establish drive
parameters)
217-XXX-000 (Failed hard disk drive test)
Note: If RAID is configured, the hard disk
drive number refers to the RAID logical
array.
217-XXX-001 (Failed hard disk test)
Note: If RAID is configured, the hard disk
number refers to the RAID logical array.
FRU/action
1. Reflash or update firmware for ISMP.
2. System board.
v Run diagnostics panel LED test for the failing LED.
1. Operator information card
2. System board
v System board
v System board
1. SCSI backplane
2. SCSI backplane cable
3. System board
1. Fan
2. System board
1. DIMM Location slots 1-4 where nn = DIMM location.
Note: nn 1=DIMM 1; 2=DIMM 2; 3=DIMM 3; 4=DIMM 4.
2. System board.
1. See error text for failing DIMMs.
2. System board.
1. Microprocessor 1
2. System board
1. Microprocessor 2
2. System board
1. Rerun the test using another diskette.
2. Cable.
3. Diskette drive.
4. System board.
1. Rerun the test using another CD-ROM.
2. CD-ROM drive cables.
3. CD-ROM drive.
4. System board.
1. Check cable and termination.
2. SCSI backplane.
3. Hard disk drive.
v Hard disk drive 1
v Hard disk drive 2
Chapter 6. Symptom-to-FRU index
91