BASIC INSTALLATION
Be sure to select a control panel installation site that is not easily
accessible to intruders. Leave at least 2" around the panel box to
permit adequate ventilation/heat dissipation. The installation loca-
tion should be dry, in close proximity to an AC source and a
ground connection.
The printed circuit board, mounting hardware and keypad should
be removed from the packaging inside panel box. Press the four
white nylon mounting studs into cabinet from the back prior to
mounting the cabinet. Before mounting the circuit board on the
back of the cabinet, pull all cables into cabinet and prepare them
for connection. Then attach circuit board to mounting studs.
Connect all zones with the 1
ding keypad zone #8.
Panel Hook-up Procedures
All panel wiring must be completed before connecting transformer
or battery. Install keypads and connect wires to keypad terminals
on panel. Bell or siren should be connected to "Bell+" and "Bell-"
terminals. Ensure correct polarity connection of sirens and pola-
rized bells.
TERMINAL CONNECTIONS
AC Terminals
Use a 16VAC transformer with a minimum 40VA rating to provide
sufficient AC power. Do not utilize any switch-controlled outlets to
power the transformer.
Siren/Bell Terminals (Bell +, Bell -)
Bells or other warning devices requiring a steady voltage output
during alarms are powered by the bell relay and the bell output
(fused at 3A). Connect the positive lead to the "Bell+" terminal and
the negative lead to relay input "NO" or "NC. Also connect a wire
between Relay C terminal and "Aux-" terminal.
Auxiliary Power Terminals
Motion detectors and other security devices requiring 12VDC volt-
age can be powered by the auxiliary power supply. A maximum of
400mA 12VDC is available from the AUX+ and AUX- terminals
when only one keypad is used with the Esprit. For each additional
keypad the auxiliary supply must be reduced by 20mA. The auxil-
iary supply is fused at 1 amp.
Keypad Terminal
(RED, BLACK, YELLOW, GREEN)
Each keypad has connectors for four colored leads; red, black,
yellow and green. Connect the lead to the corresponding colour
input terminal on the control panel and the keypad. Mount key-
pads near entry/exit doors to shorten entry/exit delay intervals. If
keypad zone #8 is to be used, connect it to the keypad with a 1
EOL resistor. If not, connect a 1
KOHM
allel to zone terminals on keypad. Up to 5 keypads can be con-
nected in parallel.
Please note: The keypad zone can be connected on all keypads
installed. However, any open keypad zones will always be indica-
ted as zone #8 on every keypad display. The keypad zone is
always a delay zone.
Zone Input Terminals (z1 to z6, fire zone #7, keypad zone #8)
Zone terminals are the loop inputs for 6 fully-programmable
by
8 ZONE SECURITY CONTROL PANEL
Installation Instruction Manual

Software Version

EOL resistors supplied, inclu-
KOHM
EOL resistor in par-
KOHM
3.2
3.1
3.1
See page 6 for VERSION 3.1 modifications
zones. Connect normally closed detectors or contacts to each
zone and jumper any unused loops with the EOL resistors sup-
plied. An open contact across the resistor or reduced loop resis-
tance in fire zone #7 will engage a pulse bell/siren.
POWERING UP THE UNIT
When keypads are installed far from the control panel, we recom-
mend that you temporarily connect a keypad close to the panel to
conduct "power-up" testing. If key switches are being installed, a
keypad must be used to conduct programming.
Connect the transformer. After 5 seconds, you can begin testing
the unit. Enter random commands on the keypad. It should "beep"
in response to these commands.
Open a zone to ensure that keypad and panel are responding to
signals. If the keypad does not respond and if no indicator lights
illuminate check for AC voltage at the "AC" terminals. If 16VAC is
flowing, then keypad wiring should be verified, as well as the key-
pad/aux. supply fuse. If this fuse has blown, check for a short
between black and red keypad wires before replacing it.
Battery Hook-up
Warning: Never connect the transformer or the battery until all
wiring has been completed. Use a 12VDC, 6.5 AH gel cell
battery. The red battery lead should be connected to the positive
battery terminal, and the black battery lead to the negative battery
terminal. Reversed connections will blow the battery fuse. The
battery should not be connected until AC connections to the panel
have been made. A "trouble" key indicator will illuminate on the
keypad if AC power is turned off and battery is connected.
SYSTEM STATUS COMMUNICATION:
Every time a key is pressed, it illuminates and the keypad beeps
to show an entry has been recognized. There are two types of
beep tones which communicate information regarding keypad
entries to the system user.
"
" beep:
CONFIRMATION
If an operation (ie. arming/disarming, programming) is correctly
entered on the keypad, or the system switches to a new
status/mode, the sounder emits an intermittent beep tone.
"
" beep:
END/REJECTION
If the system reverts to previous status, or an operation is incorrect-
ly entered on the keypad, sounder emits a continuous beep tone.
PROGRAMMING THE ESPRIT 727
Esprit system programming is performed from the keypad. The sys-
tem contains programmable memory (EEPROM) which does not
erase, even after total battery and AC loss. System automatically
reverts to "pre-power failure" status once battery/AC power are
restored. Please note: If system was "armed" prior to AC/battery
failure, it reverts to "armed" status approx. 2 minutes after power is
restored, to allow motion detectors sufficient time to warm up.
All programming pertaining to control panel operation is stored in
EEPROM sector which can only be accessed by entering the system
installer code. With the exception of the factory-set installer code
0000 and master code 0101, all other system features should be
programmed. The installer code has access to all features pro-
gramming but can't use any system functions (arming/disarming,
1
INST727-960606
http://www.paradox.ca

Advertisement

Table of Contents
loading

Summary of Contents for Paradox Esprit 727

  • Page 1: Software Version

    8 ZONE SECURITY CONTROL PANEL Installation Instruction Manual Software Version See page 6 for VERSION 3.1 modifications PARADOX SECURITY SYSTEMS 780 Industrial Blvd, St-Eustache, Quebec, Canada J7R 5V3 - Fax: (514) 491-2313 http://www.paradox.ca zones. Connect normally closed detectors or contacts to each BASIC INSTALLATION...
  • Page 2 The panel must be returned to press [ ], followed by the 4-digit default installer code 0000. ENTER Paradox Security Systems Ltd. for installer code reset. The “ ” beep will sound and the [ ] light will flash to There is a charge for this service.
  • Page 3: Programmable Outputs

    PROGRAMMABLE OUTPUTS: (address note that any zones that are to be defined as “stay” zones must "30" The memory address for programmable output options is first be “bypass enabled” (address ) Zone 7 and 8 cannot be "30" The next two digits entered assign the conditions which cause “stay”...
  • Page 4: System Disarming

    automatically been bypassed. Please note: This feature is not STAY ARMING STAY + ACCESS CODE (PRIORITY 2, 3) This feature allows the end user to partially arm the system, while recommended for regular use because bypassing zones can remaining in the protected area. Entering [ ] + access code reduce the efficiency of system protection.
  • Page 5: Warranty

    #7. WARRANTY Panic alarms: Warranty conditions for the Esprit 727 may vary from country to Pressing keys [1] and [3] simultaneously for 1 second gene- country. Please consult your local dealer for complete warranty rates a panic alarm. Panic alarms will be recorded in memory information.
  • Page 6 11- After using the keyswitch to arm or disarm the panel, the keyswitch must be disengaged in order engaged keyswitch alter- to perform the next operation. nates between arm/disarm 12- Versions hardware can be upgraded to Version by replacing the processor. Paradox Security Systems Graphic Dept. - PRINTED IN CANADA - 960606...

Table of Contents