Air-Conditioners PLA-RP·AA / PUHZ-RP·HA PU (H)-P·GAA OPERATION MANUAL FOR USER English For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
Contents 1. Safety Precautions ..................................2 2. Operation ..................................... 3 3. Care and cleaning ..................................5 4. Troubleshooting ................................... 6 5. Specifications ....................................7 1. Safety Precautions s Before installing the unit, make sure you read all the “Safety precautions”. s The “Safety precautions”...
2. Operation Replacing the Batteries and how to set the current time If no signal is transmitted and the indoor unit’s lamp does not light up even if the remote controller is operated, the batteries may have run out, so replace them with new ones as described below.
Page 4
2. Operation 2.4. Selecting a fan speed 1 Press button to select a desired fan speed. • Each time you press the button, available options change with the dis- play A on the remote controller, as shown below. ˚C Remote controller display Fan speed ˚C Middle 2...
2. Operation For wireless remote controller AUTO STOP AUTO START 1Press the button (TIMER SET). • Time can be set while the following symbol is blinking. OFF timer : A is blinking. ON timer : A is blinking. 2 Use the buttons to set the desired time.
4. Troubleshooting Before you call out a repair man, check the following table to see whether there is a simple solution to your problem. [for wireless remote controller] Problem Solution Problem Solution Unit does not operate at all. Turn main power on. Then press the Unit does not start immediately.
5. Specifications I PLA-RP·AA+PU(H)-P·GAA Model Capacity (Cooling/Heating) <kW>*1 7.70/9.20 9.60/10.50 13.30/15.60 14.20/17.00 Total Input (Cooling/Heating) <kW>*1 3.42/3.48 3.68/3.91 5.09/5.54 5.90/6.35 Power source (voltage <V>/Frequency <Hz>) – Dimension (Height) <mm>*2 258 (30) 298 (30) Dimension (Width) <mm>*2 840 (950) Dimension (Depth) <mm>*2 840 (950) Fan Airflow rate (Low-Middle2-Middle1-High) <m /min>...
Page 10