Indication
Meaning
UBG 00 00 00 00
User bit data of the timecode
generator
CTL -0:00:00:00
Data of the CTL counter
T*R 00:00:00:00
Timecode cannot be read with
the LTC reader.
U*R 00 00 00 00
User bits cannot be read with
the LTC reader.
T*R.00:00:00:00
Timecode cannot be read with
the VITC reader.
U*R.00 00 00 00 User bits cannot be read
with the VITC reader.
See "To select time data to display during playback"
(page 89) for information about how to switch
between different types of timecode.
Checking the Power Voltage and
Selecting the Fan Mode
Voltage check/Fan mode page
The first line allows you to check the battery
voltage, and the second line displays the
operating mode of the internal fans.
To select the fan mode
You can select the fan mode from the modes in
the following table.
Setting
Operation of the fans
AUTO1 (default)
The fans are controlled
automatically according to the
unit's internal temperature.
During recording, they are
controlled for quiet operation.
Normally use this mode.
AUTO2
Normally the fans are
controlled in the same way as
in MIN mode, but during
recording they are controlled
for quieter operation.
However, control for quieter
operation is limited to several
minutes or less.
Use this mode only when the
ambient temperature is normal
or lower.
Setting
Operation of the fans
MIN
In this mode, the fans operate
quietly regardless of whether
the unit is recording. This
mode is preferable for 30
minutes or more of shooting
in quiet environments such as
concert halls.
Use this mode only when the
ambient temperature is normal
or lower.
MAX
The fans rotate at maximum
speed to lower the unit's
internal temperature.
Notes
• If the internal temperature rises so high that the
TEMPERATURE CARE message is displayed, the
fan rotation speed will automatically increase to lower
the temperature.
• If the internal temperature rises so high that the TEMP
WARNING/FAN MAX message appears, the fan
mode changes automatically to MAX. After the
temperature has dropped sufficiently and the message
has disappeared, restore the original mode manually.
• When the video format is 50P or 59.94P, the fans are
controlled as in AUTO1 mode, even when AUTO2 or
MIN mode is selected, so that the higher power
consumption does not lead to higher internal
temperatures. Also, the fans do not operate more
quietly during recording.
To change the fan mode from a menu
You can also change the fan mode by using the
<OTHERS 1> page of the Camera >USER
(MAINTENANCE) menu (see page 141).

Character Data On and Off

You can enable and disable the superimposition
of character data onto the camera picture for
selected output destinations.
Character data page
Superimposition of character data can be turned
ON or OFF for each of the following destinations
individually.