free hit counter

Starter Relay; Glow Lamp Timer; Fusible Link - Baroness LM315GC Service Manual

Table of Contents

Advertisement

Starter Relay

The starter relay is located in the left side of the
hydraulic tank and controls the activation of the
starter motor.
Only if the engine starting conditions of the
interlock system are satisfied, the starter motor
can be activated. (See " "Interlock System
Operation Requirements" (Page 5-11) ")
Starter Relay_001
1
Starter relay

Glow Lamp Timer

The glow lamp timer is located in front of the
valve module and controls illumination of the
thermo-start lamp.
1
Glow Lamp Timer_001
1
Glow lamp timer
When the ignition key is set and held to the
"GLOW" position, the thermo-start lamp turns on
for 5 seconds.
The timer unit is activated with the "GLOW" and
"START" signals from the ignition key switch.
Electrical components
When the glow signal is input, the thermo-start
lamp turns on (5 seconds).
When the ignition key is set to the "START"
position (starter motor start), even during the
period of the thermo-start lamp turning on
(before 5 seconds pass), the starter start signal
is input and the lamp is turned off.
If the timer unit malfunctions, the lamp will not
turn on; however, this will not affect engine
starting.
1
ipzeta-002

Fusible Link

The fusible link acts as a main fuse for the entire
circuit and a fuse for the charging circuit.
Located in the right hood, it is equipped with a
specialized fuse (50 A) cartridge.
yvr8dl-003
Electrical system
Ignition key
Glow lamp
5 seconds
Glow Lamp Timer_002
Fusible Link_001
1
Specialized fuse
LM315GC
yvr8dl-005
1
1qgabk-002