HOW TO INSTALL CLEAN VIEW KIT (CVCK)
Clearance to Combustibles
Clearance to Combustibles
Back (from Standoffs)
Side (from standoffs)
Floor
Ceiling (from bottom of fireplace) 60 inches/150 cm
Top (from standoffs)
Top of 90 degree bend in Minimum
Enclosure of 45 to 46 inches
Top of 90 degree bend in
Enclosure over 46 inches
Top of Horizontal Pipe
Side & Bottom of Horizontal Pipe 1 inch/25.5mm / Kingsman Vent Systems
Vertical Vent Pipe
Vertical Vent Pipe
(NOTE -Floor) if installing the appliance directly on carpeting or other
combustible materials other than wood flooring, the appliance shall be
installed on a metal or wood panel, the full width and depth of the appliance.
Carpet may extend 1 inch above the floor of appliance.
For units with CVCK (Clear View Circulating Kit) see framing with CVCK
to establish floor heights
0 inches/0 mm
0 inches/0 mm
0 inches/0 mm
0 inches/0 mm
5 inches/128 mm / Kingsman Vent Systems
2
1
/
inches/64 mm / Kingsman Vent Systems
2
1
1
/
inches/38 mm / Kingsman Vent Systems
2
1 inch/25.5mm / Kingsman Vent Systems
1
1
/
inch/32mm / Simpson Duravent Systems
4
8
CAUTION:
When using CVCK
DO NOT INSTALL
a Louver assembly
1. Install optional Fan Kit (See Fan Instruction)
2. Fold two standoffs up into position & mount
with supplied Screws. (Fig. 1)
3. Hang CVCK on top of fireplace retainer tabs
and rotate down into position. (Fig. 2)
4. Using four supplied #6 screws fasten CVCK kit
to the inside frame of unit.
5. Kit is supplied with 2 valve extension knobs
align notches and slide onto valve.
6. *Do not brick or tile beyond inside area of
CVCK kit to allow for removal of door.
7. Install optional pull screen system: First slide
curtain onto rods and slide round end of rod
into side post Ref: A, using 1/2" DT screws
mount flattened end of rod to bottom side of
rod hanger bracket Ref: B, repeat this step for
opposite side.
Note: Additional Access for gasline
installation and Fan Electrical
installation. When CVCK kit is
installed in framing remove 2
screws from the right and left side
of bottom panel Ref: C. Once
screws are removed, bottom panel
can be rotated forward for access
to gas valve and fan system.