Page 1
The CT100 communicating Z-Wave thermostat operates top cover via a high-quality, easy-to-use touch screen. To set or adjust your CT100, simply touch your finger firmly to the screen. The screen will automatically light up and you will hear a Reset button “beep.”...
HOME Screen Control Screens Before you operate the CT100 please get familiar with these basic control screens. All the CT100 functions are accessed through these screens: HOME, MENU, and MANUAL. The CT100 touch screen technology allows you to select (by touching) an item and change it using the +/- arrows or the time arrows.
Page 3
MENU Screen The MENU screen is the gateway to many functions or settings of the CT100. It is displayed when you press the MENU button. [See pages 6-8 for details] Chirp set Differential to set RECOVERY set Set Time Touch this to turn the...
Page 4
MANUAL Screen The Manual Screen control screen is where you can make temporary changes to your CT100’s operation. From the HOME screen, touch the main temperature display to use this screen. [See page 9 for details] Temp Up / Temp Down arrows...
Page 5
Initial Settings Press MENU to access the following commands (from HOME screen). Set time of day Touch the Time of Day arrows to move the time selection forward or backward until it displays the current time. Touch and hold for faster setting. Backward Forward Set o F- o C display...
Page 6
0.5° to 4.0°F (.25° to 2°C). For example, if SWING is set to 2.0° F and the CT100 is set to 70°F Target Temperature, the heat cycle will start when room temperature drops to 68°F. Similarly, the cooling system will start when the room temperature increases to 72°F. The HVAC then runs and will shut off at the Target Temperature.
Page 7
Touch icon for 5 seconds; the unit will go into the PARTIAL lock mode. The user can temporarily override the CT100 target with the +/- buttons only. (1 bar) For FULL lock : Touch the (1 bar) icon again for 5 seconds to go to full lock. No changes can be (2 bars).
Page 8
CALIBRATE Your thermostat was accurately calibrated at the factory to ±1° F of actual ambient temperature. You do have the option, however, to change the display temperature to match that of a previous thermostat, or to match another thermostat already in your home. The range of change is from -6°F to +6°F or -3°C to +3°C.
Page 9
EMER (in HEAT PUMP type) If you set your CT100 for HEAT PUMP with auxiliary heat, EMER function is available on the MANUAL screen. If you touch EMER, it displays EMER|ON. Your HEAT PUMP is disabled and auxiliary heat is your sole source of heat.
The mode button sets the CT100 to HEAT, COOL, AUTO, or OFF modes. Press it once to step to the next mode. If the CT100 is in OFF and you want to return to the mode you were previously in, touch the OFF indicator on screen.