Accessible drives
12.5.2.7 Concluding steps
Perform the following procedures to complete the task:
Ê Reinstall the system fan holder as described in section
fan holder" on page
Ê Reinstall the air duct as described in section
on page
94.
Ê If applicable, close the front cover and reinstall the ID card as described in
section
"Closing the server" on page
Ê Close the side / top cover as described in section
on page 107
(rack server) or
server).
Ê When working on a rack-mounted server, secure it in the rack as described
in section
"Sliding the server into the rack" on page
If the server has been completely removed from the rack for maintenance
purposes, reinstall and secure it in the rack as described in section
"Mounting the server in the rack" on page
Ê Reconnect the AC power cords to the power supply units and secure them
with PSU cable brackets as described in section
the mains" on page
652
379.
"Mounting the side cover" on page 114
125.
Upgrade and Maintenance Manual
"Installing the system
"Installing the system air duct"
104.
"Mounting the top cover"
124.
122.
"Connecting the server to
(tower
TX300 S7 / RX350 S7