Page 3
Ths product conforms to the EMC Drectve 89/336/EEC and the Low Voltage Drectve 73/23/EEC. The complete Declaraton of Conformty s avalable from Ohaus Corporaton. ...
Page 4
Disposal In conformance wth the European Drectve 2002/96 EC on Waste Electrcal and Elec- tronc Equpment (WEEE) ths devce may not be dsposed of n domestc waste. Ths also apples to countres outsde the EU, per ther specfc requrements. Please dspose of ths product n accordance wth local regulatons at the collectng pont specfed for electrcal and electronc equpment. If you have any questons, please contact the responsble authorty or the dstrbutor from whch you purchased ths devce. Should ths devce be passed on to other partes (for prvate or professonal use), the content of ths regulaton must also be related. Thank you for your contrbuton to envronmental protecton.
Page 5
nstallaton. If ths equpment does cause harmful nterference to rado or televson recepton, whch can be determned by turnng the equpment off and on, the user s encouraged to try to correct the nterfer- ence by one or more of the followng measures: • Reorent or relocate the recevng antenna. • Increase the separaton between the equpment and recever. • Connect the equpment nto an outlet on a crcut dfferent from that to whch the recever s con- nected. • Consult the dealer or an experenced rado/TV techncan for help Industry Canada Note Ths Class B dgtal apparatus comples wth Canadan ICES-003. Cet apparel numérque de la classe A est conforme à la norme NMB-003 du Canada. EMC Australia / New Zealand: AS/NZS4251.1, AS/NZS4252.1 ISO 9001 Registration In 1994, Ohaus Corporaton, USA, was awarded a certfcate of regstraton to ISO 9001 by Bureau Ver- tus Qualty Internatonal (BVQI), confrmng that the Ohaus qualty management system s complant wth the ISO 9001 standard’s requrements. On May 15, 2003, Ohaus Corporaton, USA, was re-regstered to the ISO 9001:2000 standard. Registro ISO 9001 En 1994, Bureau Vertus Qualty Internatonal (BVQI) le otorgó a Ohaus Corporaton, EE.UU., un certf- cado de regstro ISO 9001 el cual confrma que el sstema admnstratvo de caldad de Ohaus cumple con los requermentos del estándar ISO 9001. En mayo 15 del 2003, Ohaus Corporaton, EE.UU., fue regstrada nuevamente al estándar ISO 9001:2000. Enregistrement ISO 9001 En 1994, le Bureau Vertus Qualty Internatonal (BVQI) a octroyé la certfcaton d’enregstrement ISO 9001 à Ohaus Corporaton, États-Uns d’Amérque, confrmant que le système de geston de la qualté Ohaus état conforme aux condtons normalsées de l’ISO 9001. Le 15 ma 2003, Ohaus Corporaton, États-Uns d’Amérque, a été ré-enregstrée à la norme ISO 9001:2000.
Page 6
SD SERIES BENCH SCALE EN-1 Ohaus SD Series Bench Scale INSTRUCTION MANUAL • The contents of ths manual apples to all models of the SD Seres Bench Scale. • Calbraton weghts are not provded wth ths product. • For best results, use the product wthn the specfed operatng temperature range. • For best accuracy, perform your measurements n a clean envronment, free of electrostatc and magnetc felds, dust and drt, mosture, vbraton and ar currents. • Use your SD Seres Bench Scale wth care, gently loadng tems to be weghed on the center of the platform. Avodng rough treatment wll ad n extendng the lfe of your Scale.
Page 7
EN-2 SD SERIES BENCH SCALE Introduction Ths manual covers operaton for the Ohaus SD Seres Bench Scales. Unpacking SD Seres Bench Scale s shpped wth the followng components: • Indcator • AC Power Adapter • Scale Base • Ths Instructon Manual • Mountng Brackets • Warranty Card Leveling Scale Platform The Scale Base should be placed on a level, stable surface before operaton. Models SD75L and SD200L are equpped wth adjustable levelng feet. Adjust the four levelng feet under the platform to level t. Power Options AC Adapter Operation • The AC Adapter (ncluded) may be used to power the system when battery power s not avalable. • Check that the AC nput power as marked on the Adapter matches the avalable power source. • Connect the round plug of the AC Adapter to the power nput jack at the sde of the Indcator housng. See Fgure 1. • Plug the AC Adapter nto an AC power outlet. Fgure 1. Connectng Adapter Plug to Indcator.
SD SERIES BENCH SCALE EN-3 Battery Installation (Optional) • Open the battery cover on the bottom of the Indcator and nstall three “C” sze (LR14) alkalne batteres nto the compartment. Orent the batteres as shown on the nsde cover. Close the battery cover. NOTE: Batteres are not ncluded. Fgure 2. Battery Installaton. CAUTION: Do not dispose of used batteries in domestic waste. Follow the proper disposal or recycling requirements in accordance with local laws and regulations. Indicator Mounting and Placement Options • Table Top Placement: The Indcator may be placed on a flat table surface wthout addtonal hardware. Four rubber feet provde reduced slppage on most surfaces.
EN-4 SD SERIES BENCH SCALE 120mm / 4.72” Fgure 3. Drect Wall Mount Arrangement. • Bracket Wall Mounting/Table Mounting: Attach the two mountng brackets as shown n Fgure 4. Poston the Indcator where desred on the wall or table. Install 2 screws (not suppled) nto the ends of each bracket to secure them to the surface. When mountng to a wall wthout sold backng, use approprate anchorng hardware. MOUNTING NOTES: 1. When attachng brackets: Insert round pns nto holes at bottom of Indcator, slde each bracket back to lock n place. 2. Mountng brackets may be attached n two dfferent orentatons to provde optmum vewng angle. 3. Some mountng postons may requre that the brackets be attached to the work surface before beng attached to the ndcator. 120mm / 4.72” Fgure 4. Bracket Wall & Table Mount Arrangements.
SD SERIES BENCH SCALE EN-5 Product Features & Operation Fgure 5. Indcator Panel Controls. Two Button Keypad • ON/ZERO Off : A short press turns on the scale when t s off. When the scale s on, a short press zeroes the scale, and a long press turns the scale off. • UNITS Cal : A short press changes the weghng unt and weghng mode. A short press ntates countdown durng Dynamc Weghng Mode. A long press ntates the calbraton process. Display Window Large 7-Segment Numeric Characters: • Weght (mass) values are shown usng 4 dgts ncludng negatve sgn and decmal places. Prompts for calbraton and possble error condtons are also shown usng these dgts. Stable Reading Indication : A • wll appear n the lower left corner of the dsplay to ndcate when the readng s stable. Weighing Unit Indication •...
EN-6 SD SERIES BENCH SCALE Low Battery Indication • : The battery symbol on the left sde of the dsplay ndcates a low battery condton. When frst dsplayed , approxmately 12 hours of operaton reman. When the battery s fully depleted, the scale wll momentarly dsplay “Lo bAt” and shut off. Operation Power Up Test : When the ON/ZERO Off button s pressed, the scale • s turned on, all dsplay segments wll appear for a short tme, followed by the software verson. The dsplay wll then reset to zero. Zero Function : By pressng the ON/ZERO Off button, the scale dsplay • returns to zero. When addng addtonal mass, the ON/ZERO Off button may be used repeatedly untl the full capacty of the scale s reached. When a contaner s used, the ON/ZERO Off button may be used to smulate a Tare functon. Addtonal mass may then be added as a NET weght. When removng both the sample and contaner from the scale, a negatve value may be dsplayed. Zero the scale agan before subsequent usage. NOTE: The ON/ZERO Off button wll perform a true zero settng functon when dsplayed values are wthn +2% of full capacty. Above 2%, the range s lmted to full capacty by subtracton.
SD SERIES BENCH SCALE EN-7 Auto Shut-Off • : To extend battery lfe, the scale wll automatcally turn off after approxmately four mnutes of nactvty. Ths feature s only actve durng battery operaton. Dynamic Weighing 1. Wth platform empty, press the UNITS Cal button untl the ndcator • flashes next to the desred measurng unt. 2. Place a mass on the platform. The scale wll show “-A-”. NOTE: If usng a contaner, press ON/ZERO Off to tare the weght and return to zero. 3. Wth a mass on the platform or contaner, a short press of UNITS Cal wll start the averagng countdown from 5 seconds. 4. The averaged weght s then dsplayed. The ndcator • stops flashng when the process s complete. 5. The dsplay wll hold untl a button s pressed. 6. To repeat the process press UNITS Cal wth a mass on the platform or contaner. 7. To Ext, remove the mass from the platform or contaner and press UNITS Cal.
Page 13
EN-8 SD SERIES BENCH SCALE Calibration For best results, calbrate the scale at regular ntervals. (Calbraton weghts are not suppled wth the scale.) CAUTION USE EXTREME CARE WHEN HANDLING CALIBRATION WEIGHTS AS THEY ARE VERY HEAVY. IMPROPER LIFTING METHODS OR MISUSE OF CALIBRATION WEIGHTS MAY RESULT IN PERSONAL INJURY. MULTIPLE WEIGHTS MAY BE USED TO EQUAL THE REQUIRED CALIBRATION WEIGHT. 1. Allow the scale to warm up and stablze for a least two mnutes before commencng the calbraton procedure.
Page 14
SD SERIES BENCH SCALE EN-9 5. After the zero s captured, the requred span calbraton weght n the selected unt s dsplayed. 6. Place the calbraton weght on the platform and press ON/ZERO Off button. The dsplay wll agan show “-C-”. 7. After span capture, the dsplay wll return to the normal weghng mode. NOTE: The message “CAL E” wll appear f an ncorrect calbraton weght was appled. Repeat the procedure usng the correct calbraton weght. Calibration Locking: By use of an nternal swtch, the calbraton functon may be locked (dsabled), and unauthorzed recalbraton prevented. 1. Wth the scale powered off, remove the back housng secton of the ndcator by unscrewng the four screws at the bottom. 2. Slde the swtch on the PCB (marked SW3) to the poston marked “CAL LOCK”. 3. Reassemble the housng. 4. If requred, place tamper evdent sealng labels over the screw holes or over the housng edges. If later recalbraton s requred, the housng wll need to be reopened and the lock swtch returned to the orgnal poston. NOTE: When the lock swtch s set to the CAL LOCK poston, the power-on zero range s reduced to 10% of full capacty.
Page 15
EN-10 SD SERIES BENCH SCALE Specifications (Standard Base Models) Model SD35 SD75 SD200 Capacty x Readablty 35 x 0.02kg 75 x 0.05kg 200 x 0.1kg 77 x 0.05lb 165 x 0.1lb 440 x 0.2lb Weghng Unts kg, lb Modes Smple Weghng, Dynamc Weghng Calbraton Weghts 25kg/50lb 50kg/100lb 100kg/200lb Stablzaton Tme Wthn 3 seconds Zero Range To capacty by subtracton Maxmum Overload 150% Error Indcatons: “E” - Over load, Under load, Power on Over/Under load “CALE” - Calbraton Error “UnSt” - Unstable at Power on “ErrE” - Memory Error “Lo bat OFF” - Low battery shut down “Lo Lne OFF”...
Page 16
SD SERIES BENCH SCALE EN-11 Specifications (Large Base Models) Model SD75L SD200L Capacty x Readablty 75 x 0.05kg 200 x 0.1kg 165 x 0.1lb 440 x 0.2lb Weghng Unts kg, lb Modes Smple Weghng, Dynamc Weghng Calbraton Weghts 50kg/100lb 100kg/200lb Stablzaton Tme Wthn 3 seconds Zero Range To capacty by subtracton Maxmum Overload 150% Error Indcatons: “E” - Over load, Under load, Power on Over/Under load “CALE” - Calbraton Error “UnSt” - Unstable at Power on “ErrE” - Memory Error “Lo bat OFF” - Low battery shut down “Lo Lne OFF” - Low lne voltage shut down (Power Adapter) Underload Indcaton Negatve value Auto Shut-Off 4 mnutes no actvty (battery operaton only) Battery Operatng Tme...
Page 17
EN-12 SD SERIES BENCH SCALE 210mm / 8.27” 53mm /2.09” 0º 50º 70º Fgure 5. Indcator Overall Dmensons, Avalable Vewng Angles. 316mm / 12.44” 520mm / 20.5” Standard Base Large Base Fgure 6. Scale Base Overall Dmensons.
SD SERIES BENCH SCALE EN-13 LIMITED WARRANTY Ohaus products are warranted aganst defects n materals and workmanshp for duraton of the warranty. Durng the warranty perod Ohaus wll repar, or, at ts opton, replace any components) that proves to be defectve at no charge, provded that the product s returned, freght prepad, to Ohaus. Ths warranty does not apply f the product has been damaged by accdent or msuse, exposed to radoactve or corrosve materals, has foregn materal penetratng to the nsde of the product, or as a result of servce or modfcaton by other than Ohaus. In leu of product regstraton, the warranty perod shall begn on the date of shpment to the authorzed dealer. No other express or mpled warranty s gven by Ohaus Corporaton. Ohaus Corporaton shall not be lable for any consequental damages. As warranty legslaton dffers from state to state and country to country, please contact Ohaus or your local Ohaus dealer for further detals.