Section III Maintenance

3.1 Maintenance chart

• In addition to the following maintenance table, the platen mat must be cleaned as
part of regular service calls.
• The timing of regular maintenance is determined on the basis of the number of
ADF original feed count. (F7-06)
Part name
Original feed roller/DFP roller
Original pick-up roller
Original detecting sensor
Registration sensor
Original exit sensor
Original support roller
Transport roller
Registration roller (upper)
Registration roller (lower)
Original exit roller (left)
(right)
Torque limiter spring

3.2 Cleaning

Clean each rollers.
Transport roller
Original support roller
Maintenance interval
Part number
Cleaning Replacement
FFPMA0604
60,000
FFPMA0605
60,000
GP1A73A
120,000
FFPMA0609
60,000
FFPMA0607
60,000
FFPMA0606
60,000
FFPMA0608
60,000
FFPMA0602
60,000
FFPMA0603
FFPLR0287
120,000
Exit roller
Original feed roller
Pick-up roller
DFP roller (lower)
Registration roller
Remarks
120,000
Brush, air blower,
120,000
isopropyl alcohol (IPA)
Note: •Rollers should be
–––
cleaned with water
and cloth.
–––
–––
•Use of IPA
–––
(Isopropyl alcohol)
–––
should be used
sparingly.
–––
(Lubrication)