6.0 Other Operating Values
Description
Modulation Frequency
Total output power
Steady State Efficiency
Control scheme
Peak-to-peak ripple voltage
Static load regulation
Dynamic load regulation
7.0 Board Photos
8.0 Quick Start
Recommended Equipment:
- IEEE 802.3at compliant PSE or a regular DC Lab Power
Supply
- Electronic Load
- Multimeter
- Oscilloscope
www.national.com
Operating Values
FIGURE 5. Board Photo
- Ethernet Cable
Test Procedure:
If PSE is used
1. Connect output of PSE to J300 of the eval board via eth-
ernet cable.
2. Connect test point P102 on the eval board to the positive
terminal of the electronic load. Connect test point P103 on the
6
Parameter
Value
Frequency
250
Pout
25
Efficiency
85
Control scheme Current Mode
Vout p-p
20
Static load
50
Dynamic load
75
Unit
KHz
W
%
mV
mV
mV
boardphoto1