5-2. RAS-13GKP-ES2 / RAS-13GA-ES2

RAS-13NKP-AS2 / RAS-13N2A-AS2

Cooling
0.39m
(Connecting pipe)
∅12.7
P
O.D.:12.7mm
Packed valve
(∅12.7)
Cooling
Cooling Compressor
Cooling
50Hz
Standard
Cooling
Overload
Low temperature
Note :
• Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Indoor unit
Heat exchanger
Cross flow fan
PA150X2C-4FT
Accumulator
Heat exchanger
Propeller fan
Outdoor unit
Standar d
Surface temp. of heat
pressure P
exchang er inter changing
(MPaG)
0.80
1.04
0.72
− 14 −
FILE NO. SVM-06027
T1
Packed valve
(∅6.35)
Capillary tube
∅1.7x700
Refrigerant
R410A : 0.98 kg.
Mark(
)means check points of Gas Leak.
Fan speed
(indoor)
pipe T1 (°C)
High
10.0
15.0
High
2.0
Low
0.49m
(Connecting pipe)
∅6.35
O.D.:6.35mm
l
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
27/19
35/24
32/23
43/26
21/15
21/15