2-3. Va/Vs Voltage Adjustment

2-3-1. Required Equipment

. Digital multi meter
. Signal generator
Input signal: Input1 (RGB, D-Sub) 1024 x 768@60 Hz (Recommended pattern), 100 % white pattern

2-3-2. Vs Voltage Adjustment

1. Check the label on the right upper side of PDP panel
2. Turn the volume (1VR600) to be "Vs Voltage" on the label.
Check point: 2, 3-pins (Y board)
It is normally set in the range between 180 V and 195 V.

2-3-3. Va Voltage Adjustment

1. Look at the label on the right upper side of PDP panel
2. Then turn the volume (1VR700) to be "Va Voltage" on the label.
Check point: 10-pins (Y board)
It is normally set in the range between 55 V and 65 V.
2-4
2, 3 pins
10-pin
1VR600
1VR700
FWD-42PX2