OJ Electronics WLM2 User Manual
Hide thumbs Also See for WLM2:

Advertisement

57640A 11/08 (DJU)

User Manual

WLM2
WLTA
WLTD
WLTP WLCT2
www.oj.dk

Advertisement

Table of Contents
loading

Summary of Contents for OJ Electronics WLM2

  • Page 1: User Manual

    57640A 11/08 (DJU) User Manual WLM2 WLTA WLTD WLTP WLCT2 www.oj.dk...
  • Page 2 CONGRATULATIONS Congratulations with you new control system for underfl oor heating and cooling. The control system has been developed to provide a temperature control system for room heating and cooling, integrating the switching of primary heating and cooling sources with the control of water temperature and mixing devices.
  • Page 3: Table Of Contents

    Quick guide WLCT2 programmable Room controllers ........4 Quick guide for Master modules ..............5 Trouble shooting ..................... 6 INSTRUCTIONS Master with Display Type WLM2 ..............7 Introduction ..................... 7 Supply Water Temperature Control ..............9 Using outdoor compensation module for weather compensation ....9 Service Menu ....................
  • Page 4: Quickguides

    QUICKGUIDES QUICK GUIDE ANALOGUE ROOM SENSORS These room sensors have an adjustment knob, which enables you to increase or decrease the room temperature setting by up to 4˚C. room sensors type WLTM-19 and WLTD-19 have a slide switch for selecting the mode of operation of the room sensor.
  • Page 5: Quick Guide For Master Modules

    To adjust the night temperature, press the up button until the moon is displayed and press OK button. Now use the up and down buttons to select the temperature required, and press OK button. Other advanced settings can be changed-See section “Master with display type WLM2”.
  • Page 6: Trouble Shooting

    TROUBLE SHOOTING - If any LED is fl ashing on master - Please refer to section “Error indication”. Room is too cold. (After running for at least 48 hours) The room sensor is placed in a position that does not represent the general temperature in the room.
  • Page 7: Instructions

    INSTRUCTIONS Master with Display Type WLM2 Introduction WLM2-1BA - 3BA WLM2-1FS -3FS WLM2-1AO and WLM2-3AO The masters type WLM2-1BA and The masters type WLM2-1FS and The ADD ON type WLM2-1AO -3BA are pre-set and need no WLM2-3FS are provided with graphic and WLM2-3AO is an extension adustment.
  • Page 8 Moving Around in the Menu By using the (△) (UP), and the (▽) (DOWN) you move through the main menu into sub menus. The ✓ description of these submenus can be seen below. If a value needs to be changed, then press ( (CONFIRM) button once, and alter the value with the (△) (UP) and (▽...
  • Page 9: Supply Water Temperature Control

    Using supply water sensor for limitation of supply water: A limit sensor should be used with the WLM2 1FS & WLM2 3FS, but can be used without the weather compensation module (WLOC-19). In this case the master will control the supply water temperature fl...
  • Page 10 Max supply temperature The max allowed supply water temperature is set according to the design requirements of the installation (line A on the curve). This is the safely maximum. Weather compensation Winter A design outdoor temperature and the corresponding design supply water temperature are set (point B).
  • Page 11: Service Menu

    Service Menu Service menu 55ºC Push accept to enter The controller will automatically return to main menu after 30 minutes. Software version OK no failures E0 to E11 if a failure is present. See page 13 for explanation. LS= Low signal on wireless room sensors/controllers LB= Low battery on wireless room sensors/controllers Submenu 2 Push accept to enter and see which unit has the failure...
  • Page 12 Read-out -2.4°C Outdoor temperature Read-out ⇄ 49.2ºC Actual supply water temperature 39.2ºC Actual application sensor temperature Read-out 44.4ºC Calculated setpoint by the controller for the supply water temperature Push accept for 3 sec. to change PI-action & 0-10V out Read-out Control signal for the mixing valve.
  • Page 13: Using Cooling Functions

    INSTRUCTIONS Using cooling functions If the installation is capable of doing cooling, a WLAC-1 switching module is installed. To enable cooling, switch the slider on the right hand side to the cooling position. The system now switches into cooling with a set point than is 3˚C above the master day set point. (In case the WLAC-1 module is connected to a BMS controlled signal, the BMS system will make the decision when to switch to cooling –...
  • Page 14 Additional information Master Settings Factory settings BA/FS Cooling mode Day cooling temperature Day heat temperature + 3°C Night cooling temperature Day cooling temperature + 3°C DEW point safety zone DEW point + 3°C Room temperature control PI - control P = 4°C I = 90-180 sec K-factor = 0.1 Floor Limit temperature control...
  • Page 15: Error Indication

    The error number will be indicated by the number of fl ashes, with a pause of less than a 1/2 second between the fl ashes. The indication will be followed by a pause of 2 seconds, following which the sequence will be repeated. The failure code can also be seen in the service menu on WLM2-FS MASTERS (submenu 2).
  • Page 16 Flashing output LED (red): The appropriate output channel LED can fl ash, indicating that the room sensor or room contoller on that channel has a fault/error. The failure code can also be seen in the service menu (submenu 2a). E1, 1 fl ash The master has lost communication to the room sensor.
  • Page 17: Type Wlct2 (And Wlct2/R/Hw/2)

    In addition to the immediate area of control set, within the WLCT2-x9, and selected via the ‘AREA’ setting contained within its internal menu, the WLCT2-x9 can control the time and temperature characteristics of other sensor (up to 14) fi tted to the WLM2 master, this has been designed to maximise comfort and effi...
  • Page 18 Display Automatic Manual Time and mode mode temperature Day number 4-event symbol Wake Night Home Setting the room controller into operation First time power is connected the clock and day will be fl ashing and must be set. If you need to adjust the time of the thermostat at a later date, insert a pin into the hole marked (see fi...
  • Page 19 ArEA - (Group of rooms) The rooms that are to be set as part of the WLCT2 area will follow the temperature settings of the room controller example, an area could be the living room, kitchen, and children’s rooms, having a high room temperature requirement during afternoon and early evening, and a lower temperature during the early part of the day and at night.
  • Page 20: Daily Use Of The Room Sensor

    Daily Use of the room sensor 4-Event Clock Mode The day has been split into 4 events describing a typical day. When the room sensor is in Wake up this 4-event mode it will change the temperature to the required level automatically at the programmed times.
  • Page 21: Programming 4-Event Clock Time And Temperature

    Programming 4-Event Clock Time and Temperature For each event, the start time and required temperature needs Press OK ( ) button for 3 secs. to begin programming to be set. Day 1 - 5 For example, in the morning you wish the heating to start at 07:00 and the temperature to rise to 25˚C.
  • Page 22: Advanced Settings And Read-Out

    Advanced Settings and Read-out Press both UP (△) and DOWN (▽) buttons together for 3 seconds. INFO is displayed. Continue pressing the UP(△) button until you reach one of the desired sub menus, PRO, Hi Li, Scal, and ArEA (For explanations, see below.
  • Page 23 Hi Li - Floor sensor. Max and min allowed temperature of the fl oor surface A limit sensor can be connected to the room controller. Max limitation is used for safety to prevent high fl oor temperatures. For example wooden fl oor constructions which should not be allowed to exceed a maximum of 27˚C.
  • Page 24 Set the Channels / Rooms (Ch) to ON if they should follow the settings of this clock thermostat. In total 14 channels / rooms can be controlled. This menu is only visible on 2 step controllers (WLCT2-x9/2) 2 st 2 step – Change of values in 2 step function. Press the DOWN (▽) button to activate or de-activate the 2 step function.
  • Page 25 Adaptive function This function enables the thermostat to calculate when it needs to switch ON so that the required temperature is reached at the set time. With a start time of 07:00 therefore, the thermostat may switch ON as early as 06:00 so that the desired temperature of 2 5˚C is achieved by 07:00.
  • Page 26: Reset To Fatctory Settings - Room Controllers

    Reset to fatctory Settings - room controllers NOTE: If more than one WLCT2 is present on the system, please copy this page. Press the pin button R for 3 secs. and the thermostat returns to Group Room factory settings. Remember to set time, day and area. Ch 1 Ch 2 4-event time and temperature...
  • Page 27: Domestic Hot Water Control

    It is possible to control a radiator circuit room temperature with a special version of the WLCT2 called a WLCT2-X9/R) to ensure optimum energy saving. The controller measures the temperature in the room, and a zone valve is then controlled via the WLM2 master, which in turn activates the boiler on demand.
  • Page 28: Waterline Room Sensors

    ±4°C adjustment is available. On the Master WLM2-1FS and WLM2-3FS, if the temperature setting is changed, then the default temperature for all the rooms is changed, but each WLTA, WLTM or WLTD Room sensor is locally adjustable with its own adjustment knob. With this knob the temperature setting from the Master can be increased or decreased by 4°C for that specifi...
  • Page 29 OJ ELECTRONICS A/S OJ ELECTRONICS UK OJ ELECTRONICS A/S STENAGER 13B CRUSADER PARK C/O ROBERT BIELECKI DK-6400 SØNDERBORG WARMINSTER UL. BRZOZOWA 4 DENMARK WILTSHIRE, BA12 8SP 58-160 SWIEBODZICE UNITED KINGDOM POLAND T.+45 73 12 13 14 T.+44 01985 213 003 T.
  • Page 30: Zone Chart

    Zone Chart Example Thermostat Thermo heads / Output Zone W adjustment CH 1 Kitchen 3 loops marked 1, 2 and 3 and MIN limit sensor The following chart enables you to write down the zone name, the number of loops serving it, and the control thermostat type.