7
WIRING DIAGRAM
MODELS PKH18FL, PKH24FL, PKH30FL, PKH36FL WIRING DIAGRAM
MF
1
2
3
C
I.B
FAN
1 3 5
(WHT)
X4
FC
X4
SW3
ON
OFF
12
SW2
SW5
SW8
SW1
ON
ON
OFF
OFF
1
2
3
4
5
6
1
2
3
4
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9
10
MODELS
18FL
24FL
30FL
ON
ON
ON
SW7
OFF
OFF
OFF
12 3
12 3
12 3
[LEGEND]
SYMBOL
P.B
INDOOR POWER BOARD
INDOOR CONTROLLER BOARD
I.B
CN2L
CONNECTOR(LOSSNAY)
CN51 CONNECTOR(CENTRALLY CONTROL)
FC
FAN PHASE CONTROL
SW1
SWITCH(FUNCTION SELECTOR)
SW2
SWITCH(ADDRESS SELECTOR)
SW3 SWITCH(EMERGENCY OPERATION)
SW5 SWITCH(MODEL SELECTOR)
SW6
SWITCH(TWIN/TRIPLE SELECTOR)
SW7
SWITCH(MODEL SELECTOR)
SW8 SWITCH(OPTION)
SW9 SWITCH(MODEL SELECTOR)
X4
RELAY(FAN MOTOR)
F1,F2
FUSE(6A/250V)
ZNR
VARISTOR
LED(DC12V POWER)
LED1
LED2
LED(DC5V POWER)
C
CAPACITOR(FAN MOTOR)
MF
FAN MOTOR
NOTES:
1.Since the indoor fan motor(MF)is connected with 230V power,if 208V power is used,change the dip switch(SW8)on
the indoor controller board as shown in fig:*1.
fig:*1
Indoor fan motor(MF)for 208V.
2.Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing.
3.Indoor and outdoor connecting wires are made with polarities, make wiring matching terminal numbers.
4.Symbols used in wiring diagram above are,
5.Emergency operation
If remote controller or microcomputer fails but there is no other trouble emergency operation is possible by setting
dip switch(SW3<I.B>) on the indoor controller board.
[Check items]
(1) Make sure that no other trouble exist in the outdoor unit.Trouble with the outdoor unit prevents emergency operation.
(2) Make sure that there is no trouble with the indoor fan.
Emergency operation will be continuous run with the power ON/OFF(ON/OFF with the remote controller is not possible).
[Emergency operation procedure]
(1) Set the dip switch(SW3<I.B>)on the indoor controller board to 1 on and 2 off for cooling and 1 • 2 on for heating.
(2) Turn on outdoor unit side circuit breaker,then indoor unit side circuit breaker.
(3) During emergency operation indoor fan runs at high speed but auto-vane does not work.
(4) Thermostat will not function.Cold air blows out for defrosting during heating thus do not operate defrosting for a long time.
(5) Emergency cooling should be limited to 10 hours maximum
(the indoor unit heat exchanger may freeze).
(6) After every emergency operation,set all dip switches(SW3<I.B>) to OFF.
(7) Movement of the vanes does not work in emergency operation,therefore you have to slowly set them manually to the
appropriate position.
H
FS2
FS1
MV
POWER
POWER
1
3
1
3
CNDK
CND
(RED)
(WHT)
F1
F2
LED1 LED2
ZNR
SW9
CENTRALLY
REMOCON
CONTROL
POWER
ON
CN40
OFF
CN51
(WHT)
1
2
3
4
5
SW6
SW7
HEATER
DRAIN
PIPE
INTAKE
CN24
CN31
CN21
CN20
ON
(YLW)
(WHT)
(WHT)
(RED)
OFF
1 2
1 2
3
1 2 1 2
1
23
1
234
36FL
ON
RT2 RT1
OFF
12 3
5
8
7
6
88H
NAME
SW8
SW8
ON
ON
OFF
OFF
123456
123456
:Connector,
88H
5
3
RED
RED
1
6
4
BLU
BLU
TB2
2
RED
L1
BLU
L2
GRN/YLW
GR
(DC13.1V)
(AC208/230V)
P.B
GROUND
CNSK(RED)
CN2S (WHT)
TRANS
3
2
2
1
1
BZ
6
CNB
9
1
2
VANE
CN2D
CN6V
(WHT)
(WHT)
9
WIRELESS
CN90
(WHT)
4
3
REMOCON
2
2
CN22
(BLU)
1
1
TB4
BRN
3
TRANSMISSION WIRES DC12V
OUT
3
LOSSNAY
DOOR
ORN
2
2
CN2L
CN30
YLW
1
(BLU)
1
26H
GRY
GRY
SYMBOL
NAME
MV
VANE MOTOR
TB2~TB6 TERMINAL BLOCK
RT1
ROOM TEMPERATURE THERMISTOR
(32˚F /15kΩ, 77˚F /5.4kΩ DETECT)
RT2
PIPE TEMPERATURE THERMISTOR/LIQUID
(32˚F /15kΩ, 77˚F /5.4kΩ DETECT)
WIRELESS REMOTE CONTROLLER
W.R
W.B
WIRELESS REMOTE CONTROLLER BOARD
RU
RECEIVING UNIT
BZ
BUZZER
LED1
LED(RUN INDICATOR)
LED2
LED(HOT ADJUST)
SW1
SWITCH(HEATER ON/OFF)
SW2
SWITCH(COOLING ON/OFF)
HEATER
FS1,2 THERMAL FUSE
243˚F ,10A(18,24FL)/16A(30,36FL)
H
HEATER
HEATER THERMAL SWITCH
26H
88H
HEATER CONTACTOR
:Terminal block.
19
POWER SUPPLY
~(1PHASE)
AC208/230V 60Hz
W.B
LED2
LED1
RU
SW1
SW2
W.R
REMOTE
CONTROLLER
3
2
1
TB3
OUTDOOR UNIT
RG79J693H02
The drawing has been revised as some errors in
WIRING DIAGRAM have been modified.
The former drawing number is RG79J693H01.